2.0INSTALLATION INSTRUCTIONS
Ideally an exhaust system should be located directly above the appliance to exhaust steam and heat generated by the appliance.
1.Set the unit in place and level using a spirit level.
2.Ascertain that a floor drain (open gap) is convenient to the appliance drain.
3.Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
4.Remove appliance and drill holes in locations marked on floor and insert proper anchoring devices.
5.Set unit back in position and
6.Bolt and anchor appliance securely to the floor.
7.Seal bolts and flanged feet with Silastic or equivalent compound.
8.Make service connections as indicated.
WARNING: Electrical and grounding connections must comply with applicable portions of the National Electrical Code and/or other local electrical codes.
WARNING: Disconnect electrical power supply and place a tag on the disconnect switch to indicate that you are working on the circuit.
Use copper wire suitable for at least 200 degrees Fahrenheit (90 degrees Celsius). The steamer must be grounded. The wiring diagram is located on the inside right hand panel as you face the steamer.
5