Blodgett SC-10DS, SC-6DS, SC-16DS manual Service Connections

Page 4

1.0SERVICE CONNECTIONS

S

ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH 2 AMPS per compartment or to be as specified on data plate.

DRAIN: 2"IPS piped to open floor drain. No Solid Connection.

COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa).

STEAM SUPPLY: 3/4" IPS for in coming steam at 60 lbs./hr. @ 10 psi. (27 kg/hr @ 69 kPa) min.*

55.5 [1410] SC-6DS 68.50 [1740] SC-10DS 67 [1702] SC-16DS

DIMENSIONS ARE IN INCHES [MM]

 

24 [610]

 

 

15.25 [387]

 

 

 

 

 

2 [51]

 

 

 

2.75 [70]

 

 

 

3.5 [89]

 

 

 

0 [0]

 

 

 

1.5 [38]

 

 

 

9.5 [241]

S

33 [838]

 

 

28 [711]

20.5 [521]

[635]

 

25

 

 

 

 

18[457] SC-6DS & SC-10DS

S

17 [432]

[425]

 

 

8.75

[222]

 

16.75

 

6

[152] SC-16DS

 

5.75

[146]

 

 

0

[0]

 

 

SC-6DS & SC-10DS TOP VIEW

REAR FLANGED FOOT DETAIL

2 EQUALLY SPACED Ø7/16" [11mm] HOLES ON 2.5 [63] B.C.

0 [0]

2.5[64]

10 [254]

S

SC-16DS TOP VIEW

4

Image 4
Contents SC-6DS,SC-10DS and SC-16DS Important Notes for Installation and Operation Description Service Connections Installation Instructions Information to Steam Fitter ExampleInlet To Heat Operation Operating Instructions START-UPShut Down Periodic Maintenance CleaningAdjustments Troubleshooting Door Leaks