Bakers Pride Oven BLF-FC Installation, Unpacking and Handling, Assembly and Mounting, Wiring

Page 11

Automatic Lift Fryer

Installation

 

 

Installation

Serious injury, equipment damage or death could result if attempting to install this fryer yourself. Ensure that an authorized BKI service agent installs the fryer.

Unpacking and Handling

It is the owners’ responsibility to file all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage to cartons or crates is found, or if a shortage is found, note this on the bill of lading (all copies) prior to signing.

If damage is found when the equipment is opened, immediately call the delivering truck line and follow up the call with a written report indicating concealed damage to your shipment. Ask for an immediate inspection of your concealed damage item. Packaging material MUST be retained to show the inspector from the truck line.

Assembly and Mounting

1. Remove all packing materials from the interior and exterior of the fryer.

Risk of electric shock – Fryer must be secured to building structure. Follow restraining device instructions for proper installation.

2.Install an ANSI Z83.11/CGA 1.8 compliant restraining device (such as BKI part number FT0279) per the instructions below:

Mount the wall attachment according the restraining device manufacturer instructions.

Attach the spring-loaded hook on the restraining device to the eye-bolt mounted to the fryer then attach the other spring-loaded hook to the wall attachment.

3.Lock the casters so the fryer does not move. Every time the fryer is used, make sure the casters are locked so the fryer cannot move.

4.Clean the fryer pot before filling with shortening.

5.Place the DRAIN handle in the CLOSED position.

Wiring

Electrocution, equipment failure or property damage could result if an unlicensed electrician performs the electrical installation. Ensure that a licensed electrician perform the electrical installation in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI NFPA 70-20XX.

This unit, when installed by an authorized BKI service agent, must be wired for use in accordance with all applicable local, state, and federal codes. For specific electrical requirements and connections refer to the wiring diagram attached to the unit or provided in the Service Manual.

9

Image 11
Contents Automatic Lift Fryer Limited ONE Year Warranty Warranty InformationTable of Contents Introduction Safety PrecautionsSafety Signs and Messages Full Disconnection Specific PrecautionsEquipotential ground plane Safe Work Practices Keep The Casters LockedDo Not Overload The Basket With Food Keep this manual with the Equipment Be Prepared for Emergencies Safety Labels Unpacking and Handling InstallationAssembly and Mounting WiringInitial Test and Adjustment Operation Controls and IndicatorsItem # Description Function Canceling The Stir OIL Function Pressing this button cancelsAutomatic Lift Fryer Operation Start-Up Care of the ShorteningBLF-F Operation Cooking System Programming BLF-FC OperationStep Action Display Comments Product Programming Sequence Product ProgrammingProgram Product # ALF and BLF Automatic Step Action Display CommentsStart-Up Automatic Lift Fryer Operation Weekly MaintenanceScheduled Maintenance DailyTo refill the pot automatically, use the steps below Filtering ProcedureBoil-Out Procedure Automatic Lift Fryer Maintenance Filter Pad Replacement Troubleshooting Automatic Lift Fryer LI0225/0808