3 Operation

The DHV-150H can be equipped with various accessories to enhance its operation. A remote control panel must be used with the DHV-150H. There are two remote control panels from which to choose. The humidity/fan control panel is used to control humidity and the fan. The ventilation timer and humidity control panel is used to control ventilation, humidity and the fan.

3.1 Humidity/Fan Control Panel

See Figure 7: The humidity/fan control panel automatically controls the humidity of the living space. The humidity/fan control panel contains an adjustable humidity control and a fan switch. This panel should be mounted in a central area of the structure where it can accurately sense the humidity of the air in the living space. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing.

The humidity/fan control panel can be used in conjunction with the optional fresh air damper. When used with the optional fresh air damper, the fan/filter switch will act as a fresh air ventilation control. When the switch is ON (in this configuration), the fan will run, the fresh air damper will open, and fresh air will be filtered and brought into the structure. When the switch is OFF, the fresh air damper will close and the fan will operate only when the humidity control calls for dehumidification. Contact the factory for instructions on this type of installation.

3.2Ventilation Timer and Humidity Control Panel

See Figure 7: The ventilation timer and humidity control panel automatically controls both the ventilation and the humidity of the living space. The ventilation timer and humidity control panel contains an adjustable humidity control, a fan switch, and a ventilation timer. This panel will control the humidity and allow programmed ventilation of the living space. This panel works in conjunction with the optional fresh air damper to provide ventilation.

This panel should be mounted in a central area of the structure where it can accurately sense the humidity of the air in the living space. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing.

3.3 Humidity Control Adjustment

Set the humidity control to the desired humidity level for the home. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the unit's dehumidification rate; the unit will simply run longer to reduce the area's RH to the setting. The DHV-150H unit (and refrigerant-based dehumidifiers in general) will reduce a warm space's RH to a lower level than that of a cool space. It is therefore pointless to set the humidity control to excessively low levels in cool rooms; doing so will result in long periods of ineffective dehumidifier run time.

Quality humidity meters are available from the factory and are recommended to accurately monitor humidity levels.

3.4 Fan/Filter Switch

Turning ON the fan/filter switch will cause the central conditioning unit's internal fan to run continuously, whether the central conditioning unit is dehumidifying or not. This function is desirable if the central conditioning unit is used for air circulation and filtration to achieve maximum indoor air quality. When the switch is ON; air will be constantly filtered through the central conditioning unit and circulated throughout the house. When the switch is OFF the fan will operate only when the humidity control calls for dehumidification or when the ventilation timer calls for ventilation.

3.5 Ventilation Timer

The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activated, the central conditioning unit will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence. The home should be ventilated with fresh air as suggested by applicable codes and standards.

In cold climates or areas where the outdoor dew point is low at times, ventilation can be used to dehumidify the structure. This approach is often more economical than running the dehumidifier to remove excess moisture from the structure. For example, in a house that experiences condensation on the interior surface of the windows during the winter, increasing the amount of ventilation will often cure the problem.

7

Image 7
Contents Location V 1 5 0 H I n d o o r a i r Q u a l i t y S y s t e mCondensate Removal Electrical Requirements4C Ducting for Fresh Air 4A Installing Duct CollarsDucting 4B Ducting for Dehumidification4D Constant Airflow Regulator and Vent Hood Options Remove Shipping Restraints Quiet InstallationPage Ventilation Timer Fan/Filter SwitchLow Pressure Control High Efficiency Air filterTechnical Description Warranty NoticeStandard Air Filter Optional Fresh Air ReturnUnit removes some water, but not as much as expected Troubleshooting6A Checking Compressor Motor Circuits Fan ReplacementCompressor/Capacitor Replacement Refrigerant Charging6C Replacing a Compressor, Nonburn Out Remote Controls7A Humidity Control Condensate Pump Kit 7B Programmable Ventilation TimerDefrost Thermostat Electric Ventilation DamperElectric Schematics of the DHV-150H Pictorial Electrical Diagrams of DHV-150H Service Parts List DHV-150H Indoor Air Quality System Optional Parts List DHV-150H Indoor Air Quality System Limited Warranty Date Service Notes

DHV-150H specifications

The American Aldes DHV-150H is an advanced ventilation unit designed to optimize indoor air quality in residential and commercial spaces. Known for its efficiency and reliability, the DHV-150H incorporates cutting-edge technologies to ensure that both air exchange and energy conservation are maximized.

One of the standout features of the DHV-150H is its high airflow capacity. It can effectively manage ventilation requirements for spaces up to 1,500 square feet, making it an ideal solution for medium to large residences and commercial buildings. The unit boasts a robust airflow rate of 150 CFM (cubic feet per minute), enabling swift air exchange and preventing the accumulation of indoor pollutants.

Energy efficiency is a hallmark of the DHV-150H, which is equipped with an advanced heat recovery ventilator (HRV) system. This technology allows the unit to recover and transfer heat from the outgoing stale air to the incoming fresh air. As a result, the DHV-150H can significantly reduce heating costs in winter, while still maintaining a comfortable indoor environment.

In terms of construction, the DHV-150H features a durable housing made from high-quality materials that ensure longevity and resistance to corrosion. Its compact design allows for flexible installation options, whether mounted on a wall or in a ceiling, seamlessly integrating into any architectural space.

The DHV-150H also prioritizes user experience and control. With a user-friendly interface, it allows homeowners and facility managers to easily adjust settings and monitor performance in real-time. This adaptability is further enhanced by compatibility with smart home systems, enabling remote control via smartphone applications or smart home networks.

Noise reduction is another key characteristic of the DHV-150H. The unit operates at a low sound level, ensuring that it does not disrupt the tranquility of living or working environments. This is particularly important for settings such as bedrooms, offices, and healthcare facilities where a peaceful atmosphere is essential.

In summary, the American Aldes DHV-150H represents a perfect blend of efficiency, technology, and user-centric design. Its high airflow capacity, energy recovery capabilities, robust construction, and smart integration make it a top choice for those seeking reliable and effective ventilation solutions. Whether for enhancing home comfort or improving commercial air quality, the DHV-150H continues to set standards in the HVAC industry.