American Aldes DHV-150H specifications Electrical Requirements, Condensate Removal

Page 2

Avoid discharging the air directly at people, or over the water in pool areas.

If used near a pool or spa, be certain there is NO chance the unit could fall into the water or be splashed and that it is plugged into a GROUND FAULT INTERRUPTER.

DO NOT use the DHV-150H as a bench or table.

A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage.

Place the DHV-150H on supports that raise the base of the unit above the top of the flanges on the drain pan beneath it. Raising the DHV-150H will help the unit drain with gravity flow. Do not place the DHV-150H directly on structural building members without vibration absorbers or unwanted noise may result.

The DHV-150H may be suspended with steel hanger straps (plumbers tape) or a suitable alternative from structural members. Remember to place a drain pan under the unit if it is suspended above a finished area or above an area where water leakage could cause damage.

The DHV-150H should be located near the existing air handling system to minimize the required ductwork for connecting the DHV-150H to the existing air handling system. The controls for the DHV-150H are remote from the unit and must be located in the space that is to be conditioned. The controls are low voltage (24 volt) and should be connected to the DHV-150H with low voltage thermostat cable.

An external insulation kit is available for the DHV-150H. This will prevent the cabinet from sweating if the unit is installed in an unconditioned space. This kit will also increase the efficiency of the unit by eliminating unwanted heat transfer between the unit and the unconditioned space. See the optional parts list for information on the kit.

If fresh air ventilation is desired, thought should be given to the location for the fresh air ducting. A 6” round insulated duct will have to be installed on the DHV- 150H and run to the outside of the structure to bring in fresh air. Use an 8” insulated round duct for lengths of more than 50 feet or if more than 100 CFM is needed. Consult local codes for necessary distances from exhaust ports when installing fresh air return.

2.2 Electrical Requirements

The DHV-150H plugs into a common grounded outlet on a 15 or 20 Amp circuit. It draws around 12 Amps under normal operating conditions. If used in a wet area

(pool, spa room, or basement prone to flooding), a ground fault interrupter protected circuit is required.

Install the remote control panel in a central area of the structure where it will sense the relative humidity of the structure accurately. Avoid installing the control panel near HVAC supply registers, exterior doors, a pool or spa. The installer must supply the wiring between the DHV-150H and the control panel. Be sure to safely route the control wiring to prevent damage during installation. Be careful not to cross the wires when connecting the DHV-150H and the remote control panel or damage to the transformer may result.

The remote controls of the DHV-150H are powered by a low voltage circuit (24 Vac) and must NEVER contact or be connected to a high voltage circuit. The control wires leaving the DHV-150H and the remote control panels are numbered and color-coded to prevent confusion. Some of the control wires leaving the DHV- 150H may not be used with certain control panels and should be left safely disconnected with wire nuts taped onto the stripped ends. Be sure to consult the electrical schematic in this manual or inside the access panel of the DHV-150H before making the control connections.

WARNING: DO NOT ALLOW THE YELLOW LEAD FROM THE DHV-150H TO CONTACT THE RED LEAD OR ORANGE LEAD FROM THE DHV-150H OR DAMAGE TO THE TRANSFORMER WILL RESULT.

NOTE: RESET THE VENTILATION TIMER BEFORE ATTEMPTING TO PROGRAM AFTER INITIAL INSTALLATION. THE TIMER MAY NOT OPERATE CORRECTLY UNTIL IT IS RESET.

If an extension cord is required, it must have a minimum of 12 gauge conductors if 25 feet long or less and 10 gauge conductors if greater than 25 feet long.

2.3 Condensate Removal

Condensate drains by gravity via the clear hose extending from the unit. Route the hose to a suitable drain. Use care to keep the hose as flat to the floor as possible, excessive humps will prevent proper drainage.

If the DHV-150H is located too far from a drain for the attached hose to reach, inexpensive 1/2" PVC pipe can be used to extend it. It is commonly available in 10' lengths from building supply, plumbing or hardware stores. It will slide tightly inside the end of the drain hose. If more than one length of pipe is required, they can be joined with a short piece cut from the end of the drain hose.

2

Image 2
Contents V 1 5 0 H I n d o o r a i r Q u a l i t y S y s t e m LocationElectrical Requirements Condensate Removal4B Ducting for Dehumidification 4A Installing Duct CollarsDucting 4C Ducting for Fresh Air4D Constant Airflow Regulator and Vent Hood Options Quiet Installation Remove Shipping RestraintsPage Fan/Filter Switch Ventilation TimerHigh Efficiency Air filter Low Pressure ControlOptional Fresh Air Return Warranty NoticeStandard Air Filter Technical DescriptionTroubleshooting Unit removes some water, but not as much as expectedRefrigerant Charging Fan ReplacementCompressor/Capacitor Replacement 6A Checking Compressor Motor Circuits7A Humidity Control Remote Controls6C Replacing a Compressor, Nonburn Out Electric Ventilation Damper 7B Programmable Ventilation TimerDefrost Thermostat Condensate Pump KitElectric Schematics of the DHV-150H Pictorial Electrical Diagrams of DHV-150H Service Parts List DHV-150H Indoor Air Quality System Optional Parts List DHV-150H Indoor Air Quality System Limited Warranty Date Service Notes

DHV-150H specifications

The American Aldes DHV-150H is an advanced ventilation unit designed to optimize indoor air quality in residential and commercial spaces. Known for its efficiency and reliability, the DHV-150H incorporates cutting-edge technologies to ensure that both air exchange and energy conservation are maximized.

One of the standout features of the DHV-150H is its high airflow capacity. It can effectively manage ventilation requirements for spaces up to 1,500 square feet, making it an ideal solution for medium to large residences and commercial buildings. The unit boasts a robust airflow rate of 150 CFM (cubic feet per minute), enabling swift air exchange and preventing the accumulation of indoor pollutants.

Energy efficiency is a hallmark of the DHV-150H, which is equipped with an advanced heat recovery ventilator (HRV) system. This technology allows the unit to recover and transfer heat from the outgoing stale air to the incoming fresh air. As a result, the DHV-150H can significantly reduce heating costs in winter, while still maintaining a comfortable indoor environment.

In terms of construction, the DHV-150H features a durable housing made from high-quality materials that ensure longevity and resistance to corrosion. Its compact design allows for flexible installation options, whether mounted on a wall or in a ceiling, seamlessly integrating into any architectural space.

The DHV-150H also prioritizes user experience and control. With a user-friendly interface, it allows homeowners and facility managers to easily adjust settings and monitor performance in real-time. This adaptability is further enhanced by compatibility with smart home systems, enabling remote control via smartphone applications or smart home networks.

Noise reduction is another key characteristic of the DHV-150H. The unit operates at a low sound level, ensuring that it does not disrupt the tranquility of living or working environments. This is particularly important for settings such as bedrooms, offices, and healthcare facilities where a peaceful atmosphere is essential.

In summary, the American Aldes DHV-150H represents a perfect blend of efficiency, technology, and user-centric design. Its high airflow capacity, energy recovery capabilities, robust construction, and smart integration make it a top choice for those seeking reliable and effective ventilation solutions. Whether for enhancing home comfort or improving commercial air quality, the DHV-150H continues to set standards in the HVAC industry.