PREPARATION
1.Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay out the range hood’s mounting holes, wiring access and duc- twork by marking the cabinet bottom and drywall where appli- cable. NOTE: Cabinets with recessed bottoms will require wood shims to make mounting surface flush with cabinet frame.
2.Make cutouts for wiring and ductwork.
3.If the hood is to be ducted, install the ductwork so that is flush to the range hood’s mounting surface.
Refer to Figure 1 if the range hood is to be installed with a horizontal discharge.
Refer to Figure 2 and FIGURE 3 if the range hood is to be installed with a vertical discharge.
4.Run
5.Drill four 3/32” diameter pilot holes at points where mounting holes are marked in cabinet bottom.
6.Insert four (4) mounting screws, leaving approximately ¼” of thread exposed.
7.Remove and retain the mounting screws securing the 3¼” x
10” and 7” duct transitions to the hood. Install the appropriate duct transition as described in the installation section.
Installation
1.Remove the necessary duct opening and wiring knockout from the range hood.
If the range hood is to be installed as a
If the range hood is to be installed as a ducted unit, a baffle plate is provided to close off the
2.For 7” round discharge installation, refer to FIGURE 5. Se- cure 7” adapter (included) to top of hood using screws provided. Install 7” round damper (Model 895, purchased separately).
For 3¼” x 10” vertical discharge installation, refer to FIG- URE 6. Secure 3¼” x 10” transition (if used) to top of hood.
For 3¼” x 10” horizontal discharge installation, refer to FIGURE 7. If using supplied 3¼” x 10” duct transition, secure it to the range hood. Ensure that the damper flap operates fully and freely. If it does not, remove the damper flap or make necessary modifications to the installation to insure full and free operation of the damper flap.
3.Feed the wiring through the access hold and into the electrical box.
4.Align hood’s keyhole mounting slots over the four (4) partially installed screws.
5.Making sure the duct positions over the hood’s duct transition, push the hood against the rear wall. Secure hood by tightening screws.
6.Using a long blade screwdriver, reach into the discharge open- ing and make sure the damper flap operates freely (vertical discharge only).