NuTone NP64000 manual Connect Wiring ALL Blowers, Install the Blower Interior Blower

Page 9

10. CONNECT WIRING (ALL BLOWERS)

!WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.

INTERIOR BLOWER: Connect cable into wiring box using wire connectors.

Connect wires as follow: BLACK to BLACK, WHITE to WHITE and

GREEN or BARE wire under ground screw. Reinstall wiring cover. DO

NOT FORGET TO CONNECT THE GROUND.

HD00071

1) Ground screw

IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included witn in-line or exterior blower).

11. INSTALL THE BLOWER (INTERIOR BLOWER)

The blower must be installed to the rough-in plate using (4) 3/8” screws for the single blower unit and (6) 3/8” screws for the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gently (see pictures below).

HD0021

HD0022

- 9 -

Image 9
Contents NP64000 Series This unit must be grounded NP64000 Series Range Hood System Interior Blowers High capacity roof cap Select Blower Option and Install Ductwork Prepare the Installation Install Backsplash OptionalSelect Blower Option Exterior or Interior Install the ROUGH-IN Plate ALL Blowers Install the Deviator Interior BlowerChoose the Opening Interior Blower Install the Hood ALL Blowers Install the Adapter Interior BlowerInstall the Blower Interior Blower Connect Wiring ALL BlowersDual blower P8 Install the Blower Interior Blower CONT’DLight Bulbs Install FiltersHeat Lamps USE and CareOperation USE and Care CONT’DNever place highly flammable material under warming lamps Operation CONT’DNP64000 Series Service PartsSingle BLOWER/ROUGH-IN Model P5 Dual BLOWER/ROUGH-IN