NuTone ssQTXe110 Models sSQTXE080 sSQTXE110 How to set system Level, Feature selections, Table a

Page 3

models sSQTXE080 • sSQTXE110

how to set system Level

Installer, homeowner, or building science expert may adjust Broan SmartSense® ventilation system level.

Initial Setting of System Level

1.System Level is only set in Master control. If home has more than one installation then locate Master control; it is usually in master bathroom or it should be clearly marked on frame, under decorative plate, or documented on this instruction sheet.

2.Circle, mark or highlight System Level in Table A using home’s square footage and number of bedrooms.

Note: Building science experts may calculate different rate based on air infiltration measurements.

3.Circle, mark or highlight same System Level in Table B.

4.If home’s System Level is 90 then next steps are not necessary, since control’s System Level is set at factory to 90.

5.Put Master control in Program mode; press and hold SET button for 3-seconds and then release it.

6.LED should be turning on and off every second (slowblink); if it is not then repeat step 5.

7.Tap (press and release) ON or OFF paddle number of times from Table B.

8.Exit Program mode; press and release SET button twice. LED should turn off.

Changing System Level

1.Put Master control in Program mode; press and hold SET button for 3-seconds and then release it.

2.LED should be turning on and off every second (slowblink); if it isn’t then repeat step 1.

3.Press Master control’s paddle ON once and OFF once; System Level is changed back to factory setting of 90.

4.Tap (press and release) ON or OFF paddle number of times from Table B.

5.Exit Program mode; press and release SET button twice. LED should turn off.

feature selections

Vacation Mode: Used only with Master control. Temporarily disables Broan SmartSense® system. Master control will not automatically turn on its fan or any other system fan. After Program mode exit, Vacation mode is cancelled when Master control ON paddle is pressed.

Disabled Mode: When Master control is put in Disabled mode, it will not turn on any fans for automatic ventilation and recommended indoor air quality ventilation level is not assured. Manual control fan operation is not affected.

Vacation Mode

1.Put Master control in Program mode; press and hold SET button for 3-seconds and then release it.

 

 

 

 

 

 

Page 

 

 

table a

 

 

 

 

 

 

 

 

 

 

 

Floor Area (ft2)

 

 

Bedrooms

 

 

 

 

 

 

 

 

0 - 1

2 - 3

 

4 - 5

6 - 7

> 7

 

 

< 1500

30

45

 

60

75

90

 

 

 

 

 

 

 

1501 - 3000

45

60

 

75

90

105

 

 

 

 

 

 

 

3001 - 4500

60

75

 

90

105

120

 

 

 

 

 

 

 

4501 - 6000

75

90

 

105

120

135

 

 

 

 

 

 

 

6001 - 7500

90

105

 

120

135

150

 

 

 

 

 

 

 

> 7500

105

120

 

135

150

165

 

 

 

 

 

 

 

table b

ON

 

 

 

 

 

 

 

 

 

 

System

Taps

PADDLE

 

Push to

 

Level

 

 

 

turn ON

 

 

 

 

 

 

 

 

165

+5

 

 

 

 

 

 

 

 

 

 

 

 

150

+4

 

 

 

 

 

 

 

 

 

 

 

 

135

+3

LED

 

 

 

 

 

 

®

 

 

120

+2

 

 

 

 

 

 

 

SmartSense®

 

 

 

 

 

 

105

+1

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

75

-1

 

 

 

 

 

 

 

 

 

 

 

 

60

-2

 

 

Push to

 

 

 

 

 

 

 

 

 

45

-3

 

 

turn OFF

 

 

 

 

 

 

 

 

30

-4

SET

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUTTON

 

 

 

PADDLE

2.LED should be turning on and off every second (slowblink); if it is not then repeat step 1.

3.Press Master control’s ON paddle seven times.

LED should turn off and fan turn on. After 1 to 2-seconds fan turns off.

Vacation mode is maintained after power loss. Vacation mode is cancelled when Master control’s paddle is pressed ON and then OFF; System will then resume automatic operation.

Disabled Mode

1.Put Master control in Program mode; press and hold SET button for 3-seconds and then release it.

2.LED should be turning on and off every second (slowblink); if it is not then repeat step 1.

3.Press Master control’s OFF paddle seven times.

4.Exit Program mode; press and release SET button twice. LED should turn off.

Disabled mode indefinitely keeps Broan SmartSense® system from turning fan(s) on automatically to provide recommended ventilation for desirable indoor air quality. Disabled mode is maintained after power loss. Disabled mode is cancelled when Master control System Level is reset following instructions in section “Changing System Level.”

Image 3
Contents Models sSQTXE080 sSQTXE110 InstallationHow LED works HOW to link smartsense systemControl operation How System WorksTable b Models sSQTXE080 sSQTXE110 How to set system LevelFeature selections Table aHow to change control color WarrantyModels sSQTXE080 sSQTXE110 Restoring Power to control How to restore control Factory SettingsImportante AdvertenciaInstalación Modelos SSQTXE080 SSQTXE110RED DE Calidad DE Aire Bajo Techo Funcionamiento DEL ControlCómo Funciona EL Sistema Cómo Funciona EL LEDSelecciones DE Funciones Tabla aTabla B Garantía Cómo Restaurar LOS Ajustes DE Fábrica DEL ControlCómo Cambiar EL Color DEL Control

ssQTXe110, ssQTXe080 specifications

The NuTone ssQTXe080 and ssQTXe110 are advanced ventilation fans designed to enhance indoor air quality and improve the overall ambiance of any space. These models are particularly popular in residential bathrooms and kitchens, where moisture and odors can accumulate. Offering a well-rounded blend of efficiency, quiet operation, and modern features, these fans set a new standard in home ventilation technology.

One of the standout features of both the ssQTXe080 and ssQTXe110 models is their powerful airflow capability. The ssQTXe080 delivers a robust airflow of 80 CFM, while the ssQTXe110 pushes the upper limits with 110 CFM. This ensures that even in larger spaces, the air remains fresh and free of unpleasant odors and excessive humidity.

Noise levels are a crucial aspect when considering exhaust fans, and NuTone excels in this area. Both models operate at sound levels of just 0.8 sone for the ssQTXe080 and 1.0 sone for the ssQTXe110. This means users can enjoy a peaceful atmosphere, whether relaxing in the bath or preparing meals in the kitchen, without the distraction of a noisy fan.

Additionally, these fans feature a unique and innovative selection of technologies designed to optimize performance. Both models incorporate a durable and reliable DC motor, which not only enhances efficiency but also extends the overall lifespan of the fan. The energy-efficient design allows for significant energy savings, making them an eco-friendly addition to any home.

The ssQTXe080 and ssQTXe110 are easy to install, featuring a low-profile design and flexible mounting options. This allows homeowners and contractors to fit these fans seamlessly into various ceiling configurations. Moreover, they include an integrated damper that effectively prevents backdrafts, ensuring conditioned air remains inside while preventing outside air from entering.

Aesthetically, these models boast a sleek, contemporary design that complements most bathroom and kitchen decors. The white grille finish provides a clean look that can easily be painted to match the surrounding surfaces, further enhancing their integration into the home environment.

In summary, NuTone’s ssQTXe080 and ssQTXe110 ventilation fans stand out for their quiet operation, powerful airflow, energy-efficient technologies, and stylish design. These models not only contribute to a healthier indoor environment but do so while ensuring user convenience and satisfaction. Whether upgrading an existing setup or installing a new fan, the NuTone ssQTXe series is an excellent choice for modern homes.