Marley Engineered Products 3038R Ceiling Installation ALL Other Models, FAN Location & Mounting

Page 8

CEILING INSTALLATION — ALL OTHER MODELS

FAN LOCATION & MOUNTING

STEP 1 - Fan should be located in center of house, preferably in hallway or corridor. This will allow air to be drawn from all parts of living space. (See Fig. 1.)

FIG. 1

FIG. 2

OVERLAP AREA

PILOT HOLE

FAN

STEP 2 - Lightly mark a square opening on ceiling (with pencil) where shutter is to be located. Select open- ing size from chart below on Page 1. Check to be sure at least 1 1/2 inches of clearance area is available on all sides for overlap of shutter flanges. (See Fig. 2.) Drill a small pilot hole in the center of this square through ceiling.

STEP 3 - Determine ceiling joist size and spacing; the most common types are:

2 x 4 on 16” centers

2 x 6 on 16” centers

2 x 4 on 24” centers

2 x 6 on 24” centers

Now find pilot hole in attic, and tentatively lay out same square hole as on ceiling below. Adjust location of this hole so as to cut as few ceiling joists as possible and to ensure a minimum vertical clearance from roof rafters of 18” above fan. (See Fig. 3.) See installation drawings and specific instructions for your ceil- ing configuration on page 8, 9 & 10.

To make cuts through joists, use either a saber saw or circular saw. Carefully finish cut with hand saw or chisel, so that ceiling below is not damaged. (See Fig. 4.)

FIG. 3

FIG. 4

 

S

 

AFTER

 

R

 

F

 

O

 

O

 

R

 

18” MIN.

 

CLEARANCE

7

Image 8
Contents Introduction HOT AIR OUT Cool AIRAdditional Materials Required for Wall Installation only Tools and Materials RequiredShutters to be Used FAN Type Opening for Overall Size CUT CeilingAttic AIR Intake and Discharge Minimum Attic Discharge Areas RequiredCeiling Installation Model Model A3024 Shutter For Ceilings with Joists on 16 CentersFor Ceilings with Joists on 24 Centers Grommet Bracket Gasket Shutter Installation Ceiling Installation ALL Other Models FAN Location & MountingModel 3038R with Model 3230 Shutter 2 Filler 6 Framing Model 3638RModel 3038R with Model 3230 Shutter Framing Model 3638RFraming FAN Model Inside OpeningFAN Model Wiring Instructions FAN Motor Outlet BOX Control Outlet BOX Black HIBlue MED RED LOW White COM Black Brown White GND. ScrewBlue MED RED LOW White COM Brown Black FAN Motor Outlet BOXMotor Black HI FAN Size Dimensions Wall Opening Size Operating Hints and Suggestions Accessory ControlMaintenance Description QTY Model HOW to Order Repair Parts Limited Warranty

3038R, 3638R, 2438 specifications

Marley Engineered Products is renowned for its high-performance cooling solutions, and among its most notable offerings are the Marley 3038R, 3638R, and 2438 evaporative cooling towers. These models are designed with advanced technology and features that ensure efficient temperature regulation for various industrial applications, enhancing productivity while minimizing energy consumption.

The Marley 3038R and 3638R models are distinguished by their robust construction and innovative design. They are made from high-quality materials that withstand harsh environmental conditions, ensuring longevity and reliability. Both cooling towers incorporate a modular design that eases installation and maintenance, promoting operational efficiency. The Marley 3038R is ideal for medium to large industrial settings, while the 3638R caters to larger operations needing more substantial cooling capacity.

One of the standout features of these models is the use of advanced film fill technology, which enhances heat exchange efficiency. This technology maximizes water-to-air contact, promoting effective cooling with reduced water consumption. Furthermore, the fan systems in these cooling towers are equipped with high-efficiency motors that operate quietly while delivering optimal airflow, thereby minimizing power expenditure.

The Marley 2438 model is particularly notable for its compact design, making it suitable for applications where space is a constraint. Despite its smaller size, it maintains high performance levels comparable to its larger counterparts, ensuring that users do not compromise on cooling efficiency.

All three models utilize durable and corrosion-resistant components that extend their service life and reduce maintenance needs. The units are designed for easy access to critical components, making routine inspections and repairs more straightforward and less time-consuming.

Additionally, Marley Engineered Products stands out for its commitment to sustainability. These cooling towers incorporate features that optimize water usage and reduce environmental impact. The cooling solutions provide a reliable and eco-friendly alternative for users looking to meet stringent sustainability goals without sacrificing performance.

In summary, the Marley 3038R, 3638R, and 2438 cooling towers epitomize efficiency, durability, and advanced technology in industrial cooling solutions. With their robust construction, innovative fill design, and energy-efficient components, they are well-suited for a diverse range of applications, making them a top choice for industries seeking reliable cooling performance. Whether for large-scale operations or space-limited environments, Marley Engineered Products delivers cutting-edge solutions to meet the demands of modern industry.