STEP 5

Measure the horizontal length requirement including a 2” (51 mm) overlap, ie from the elbow to the outside wall face plus 2” (51 mm) (or the distance required if installing a second 90° elbow). (Fig. 21)

Always install horizontal venting on a level plane.

STEP 6

Use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent sections. The sec- tions which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (Fig. 22)

Sealing vent pipe and firestop gaps with high temperature sealant will restrict cold air being drawn in around fireplace.

FP1242

Fig. 22 Through the wall.

STEP 7

Guide the vent terminations 4” and 7” collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm). Secure the termina- tion to the wall with screws provided and caulk around the wall plate to weatherproof. (Fig. 23) As an alterna- tive to screwing the termination directly to the wall you may also use expanding plugs or an approved exterior construction adhesive. You may also attach the termi- nation with screws through the inner body into the 4” (102 mm) vent pipe however for this method you must extend the 4” (102 mm) pipe approximately 6” (152 mm) beyond the outer face of the wall.

LDVT Series Direct Vent GaS Fireplace

FP1243

Fig. 23 Apply high temperature sealant to collars or termina- tions.

Support horizontal pipes every 3’ (914 mm) with metal pipe straps. Make sure the horizontal vent pipe is in- stalled on a level horizontal plane.

Vertical Sidewall Installation

Flex Vent Pipe

NOTE: The 40” (1016 mm) flex vent is used for 90° off the top of the unit then out the back wall.

Follow Step 1 and 2 on Page 14.

Step 3

Install the four (4) spacer springs on the 4” flex vent pipe. When installing the spacer springs around the 4” pipe, stretch the spring to approximately 15” (381 mm), wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2” (51 mm). Meas- ure 6³⁄₄” (172 mm) from the end of the pipe. Place the next spring 5” (127 mm) from the previously installed spring. Place the next spring 6” (152 mm) from the last spring. Finally place the last spring 12” (305 mm) from the last spring installed. (Fig. 24)

4” Flex Vent

 

Pipe

12"

 

 

(305mm)

Spacer Spring

6"

(152mm)

5"

(127mm)

6���"

(172mm)

FP1474

Fig. 24 Install spacer springs.

10007852

15

Image 15
Contents Builder Top Vent Direct Vent Table of Contents Installation & Operating Instructions Ansi Z21.88-2005 / CSA Vented Gas Fireplace HeatersPlease Review the Following Carefully Fireplace Dimensions Framing Dimensions33LDVT 36LDVT 39LDVT 43LDVT Venting Locating Your FireplaceClearance to Combustibles MantelsGas Specifications HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationRemote ON/OFF Switch Alternate Switch LocationElectronic Gas Control Valve EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information on Assembling Vent PipesExample a How to Use the Vent GraphTwist Lock Pipes Vertical Sidewall ApplicationsSupport straps for horizontal runs Step Vertical Sidewall Installation Twist Lock PipeAlways install horizontal venting on a level plane Vertical Sidewall Installation Flex Vent Pipe7TDVSNORK Below Grade InstallationsVertical Through-the-Roof Applications Snorkel installation, recessed foundationMin 610 mm Vertical Through-the-Roof InstallationVertical Restrictor Plate 36LDVT, 39LDVT, 43LDVT Venting Components Glass Information Window Frame Assembly RemovalGlass Cleaning Operating InstructionsInstallation of Logs, Lava Rock & Ember Material Log Identification ChartLog Installation Do not place any of the lava rock material On the burner housing assemblyFlame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models 33LDVT Lighting and Operating Instructions To Turn Off Gas To HeaterWhat to do if YOU Smell GAS Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position YES Troubleshooting Honeywell Millivolt ValveRemove Window Frame Assembly Before Service Work StartTroubleshooting the Gas Control System Normal OperationAbnormal Operation SIT top Convertible Pilot PSE PilotSIT 820 Nova Gas Control Valve Fig For Model 36LDVT only Remove the rear logBrass Trim MaintenanceCleaning the Standing Pilot Control System Burner and Burner Compartment33/36/39/43LDVT Description 33/36/39/43LDVTFuel Conversion Kits Method a Optional AccessoriesFan Kits SpecificationsModel Function/s Controlled Wiring InstructionsRemote Controls Ceramic Refractory PanelsArch/Square Face Kit Optional Trim KitsScreen Door Kit Filigree Louvre KitLdvt Series Direct Vent Gas Fireplace If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings

3LDVT, 36LDVT 39LDVT, 43LDVT specifications

Vermont Casting has been a standout name in the world of cast-iron wood and gas stoves, delivering exceptional craftsmanship and innovative technology. The models 36LDVT, 39LDVT, 43LDVT, and 3LDVT are no exception. These stoves are designed to blend functionality with timeless aesthetics, making them perfect for a range of home settings.

The 36LDVT, featuring a compact design, is ideal for smaller spaces without sacrificing performance. Its advanced airflow technology ensures a clean burn, increasing efficiency and reducing emissions. The unique front-loading door allows for easy access to firewood, while the large viewing window creates an inviting ambiance, showcasing the flames beautifully.

The 39LDVT offers a larger firebox, accommodating bigger logs, making it suitable for those who enjoy longer burn times. Like the 36LDVT, it incorporates Vermont Casting's patented airflow system, optimizing heat output. One of its standout features is the innovative Intelli-Burn technology, which automatically adjusts the air intake for consistent heating. This ensures that the user spends less time managing fuel and more time enjoying the warmth.

For homeowners with more extensive heating needs, the 43LDVT provides ample heating capacity. Its robust construction not only enhances durability but also maximizes heat retention. The stove is designed with a user-friendly interface that simplifies operation. It also comes with adjustable legs, allowing for customizable installation to fit specific preferences and aesthetics.

Finally, the 3LDVT model is an epitome of efficiency, designed with modern technology while paying homage to classic wood-burning aesthetics. Its clean-line design effortlessly fits into contemporary and traditional spaces alike. The 3LDVT utilizes a secondary combustion chamber, promoting an even cleaner burn and increasing heat output. With easy-to-use controls and a reliable ignition system, users can ignite warmth at the push of a button.

Each of these Vermont Casting stoves emphasizes reliability, efficiency, and environmental friendliness. They are not just heating appliances; they represent a commitment to sustainable living without compromising on style or comfort. The blend of innovative technologies, including adjustable airflow and secondary combustion systems, positions these models as top choices for anyone looking to enhance their home heating experience with elegance and efficiency.