Vermont Casting BHDT36 installation instructions Flame Characteristics

Page 27

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below (Fig. 61, 62 and 63). If any of the flames appear abnormal call a service person.

3/8" - 1/2"

SIT PILOT

Fig. 61

PSE PILOT

Fig. 62

Fig. 63

INSPECTING THE VENTING SYSTEM

This appliance venting system was designed and con- structed to develop a positive flow adequate to remove flue gases to the outside atmosphere.

Any foreign objects in the venting system, except those designed specifically for the venting system, may cause spillage of flue gases.

To inspect the venting system, make sure the main gas valve is off. Remove glass door (See Glass Door Re- moval). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary.

MAINTENANCE

1.It is important to keep the burner and the burner compartment clean. This must be done periodically, at least once per season.

2.Clean the brass trim using a soft clean cloth, slightly dampened withlemon oil and buff with a soft clean cloth. Do NOT use brass polish or household cleaners as these products will damage the brass trim. Lemon oil can be obtaned at supermarkets or hardware stores.

3.The optional FK24 fan does require periodic clean- ing. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.

4.Contact your local representative to arrange an annual service program.

CLEANING THE STANDING PILOT

CONTROL SYSTEM

The burner and control system consists of:

burner tube

gas orifices

pilot assembly

thermopile

millivolt gas valve

 

Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve side

2.Let fireplace cool if it has been running.

3.Remove glass. (see Glass Removal)

4.Remove logs,

LOGS MAY BE HOT

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot - see Operating Section of Manual.

8. Reinstall glass.

To obtain proper operation, it is imperative that the pilot and burner's flame characteristics are steady, not lifting or floating.

Typically, the top 3/8" or 1/2" of the thermopile should be engulfed in the pilot flame. See Fig. 61 or 62.

To adjust pilot burner (by a Qualified Service Representative)

1.Remove pilot adjustment cap.

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should only be adjusted (if necessary) by a qualified service person.

- 27 -

Image 27
Contents BHDT36 Table of Contents Locating Your GAS Fireplace Installation and Operating InstructionsFireplace Dimensions Framing and Finishing Mantel ChartMantels Clearance to CombustiblesHearth GAS SpecificationsRemote Switch Installation GAS Line InstallationGeneral Venting Termination Clearances Vertical Sidewall Applications Vertical Sidewall Venting Graph HOW to USE the Vent GraphStep Vertical Sidewall InstallationStep Vertical Through Roof Applications Below Grade InstallationsVertical Thru the Roof Installation Crimped Ends Venting Components General Information on Assembling Twist Lock Vent Pipes 2286mm See page 21 for Venting Requirements for Snorkels Use the appropriate length of pipe section Below Grade Installations Vent Termination Storm Collar Roof Roof Flashing Storm Collar Twist Lock Venting Components Glass Frame Removal Glass CleaningGeneral Glass Information Louvre RemovalInstallation of Logs Flame Characteristics Lighting and Operating Instructions Honeywell Millivolt Valve SIT 820 Nova Millivolt Valve Replacement Parts List Replacement Parts Optional FAN KIT FK24 Optional Screen KIT Installation Optional Ceramic Refractory InstallationOptional Remote Control

BHDT36 specifications

The Vermont Casting BHDT36 is a standout in the world of gas fireplaces, known for its combination of classic design and cutting-edge technology. This direct vent gas hearth system is perfect for homeowners seeking both aesthetic appeal and efficient heating solutions.

One of the defining features of the BHDT36 is its expansive viewing area. With a large, picture-window front design, it allows for an unobstructed view of the mesmerizing flames, creating a captivating focal point in any living space. The fireplace is available in multiple finishes, which can easily complement various home décors, from rustic to modern.

The BHDT36 is equipped with Vermont Castings' innovative burner technology, which produces a radiant heat output. This design ensures that warmth circulates effectively, providing consistent heating throughout the room. The fireplace has an impressive heat output of up to 36,000 BTUs, making it suitable for substantial heating needs.

Efficiency is a priority for the BHDT36, which boasts an impressive 78% efficiency rating. This means homeowners can enjoy a significant reduction in energy costs while still enjoying the ambiance of a roaring fire. The direct vent system enhances efficiency further by drawing air from outside, ensuring that indoor air quality remains intact and that combustion is more complete.

Control options are another notable feature of the BHDT36. It comes with a remote control, enabling users to adjust the flame height and heat output with ease, without leaving the comfort of their seating area. The electronic ignition system ensures that starting the fireplace is simple and reliable, requiring minimal effort from the user.

For those who appreciate eco-friendly options, the BHDT36 can be outfitted with an optional natural gas converter, allowing for flexibility in fuel choice.

In terms of safety, the Vermont Casting BHDT36 meets all required safety standards, providing peace of mind to homeowners. The unit also features a built-in safety shutoff valve, automatically turning off the gas supply in case of an irregularity.

In summary, the Vermont Casting BHDT36 combines elegance, efficiency, and modern technology, making it an excellent choice for anyone seeking to enhance their home with a beautiful and functional gas fireplace. Its thoughtful design and features ensure that it can serve as the heart of the home for years to come.