Vermont Casting BHDT36 Installation and Operating Instructions, Locating Your GAS Fireplace

Page 3

INSTALLATION AND OPERATING INSTRUCTIONS

This gas appliance should be installed by a qualified installer in

IMPORTANT:

accordance with local building codes and with current CAN /

PLEASE REVIEW THE FOLLOWING

CGA-B149 (. 1 or .2) Installation codes for Gas Burning Appliances

CAREFULLY

and Equipment. or for U.S.A Installations follow local codes and/

or the current National Fuel Gas Code. ANSI Z223.1.

Remove any plastic from trim parts before turning

 

FOR SAFE INSTALLATION AND OPERATION OF YOUR

the fireplace ON.

DIRECT VENT FIREPLACE PLEASE NOTE THE

It is normal for fireplaces fabricated of steel to give

FOLLOWING:

off some expansion and/or contraction noises

 

1 . This fireplace gives off high temperatures and should

during the start up or cool down cycle. Similar

be located out of high traffic areas and away from

noises are found with your furnace heat exchanger

furniture and draperies.

or car engine.

2. Children and adults should be alerted to the hazards of

It is not unusual for your gas fireplace to give off

the high surface temperatures of this fireplace and

some odour the first time it is burned. This is due

should stay away to avoid burns or ignition of clothing.

to the curing of the paint and any undetected oil

3. CAUTION: Due to high glass surface temperature

from the manufacturing process.

 

children should be carefully supervised when they

Please ensure that your room is well

are in same room as your fireplace.

ventilated - open all windows.

 

4. Under no circumstances should this fireplace be modi-

It is recommended that you burn your fireplace for

fied. Parts having to be removed for servicing should

be replaced prior to operating this fireplace again.

a least six (6) hours the first time you use it.

If

5. Installation and any repairs to this fireplace should be

optional fan kit has been installed, place fan in the

"OFF" position during this time.

 

 

carried out by a qualified service person. A profes-

 

 

 

 

 

 

sional service person should be contacted to inspect

 

 

 

 

this fireplace annually. Make it a practice to have all

LOCATING YOUR GAS FIREPLACE

 

of your gas fireplaces checked annually. More

 

 

 

 

 

frequent cleaning may be required due to excess

 

 

 

 

lint and dust from carpeting, bedding material, etc.

 

 

 

 

6. Control compartments, burners and air passages in

 

 

 

 

this fireplace should be kept clean and free of dust and

E

A

X

 

lint. Make sure that the gas valve and pilot light are

B

 

 

 

 

turned off before you attempt to clean this fireplace.

Y

 

 

 

7. The venting system (chimney) of this fireplace should

 

 

X

 

be checked at least once a year and if needed your

 

C

 

 

venting system should be cleaned.

Y

D

 

 

 

 

 

8. Keep the area around your fireplace clear of combus-

 

 

 

 

tible materials, gasoline and other flammable vapour

 

X

 

 

and liquids. This fireplace should not be used as a

 

 

 

 

F

 

 

drying rack for clothing, nor should Christmas stock-

 

 

 

 

 

 

 

ings or decorations be hung in the area of it.

 

 

 

 

9. Under no circumstances should any solid fuels (wood,

 

 

 

 

 

 

Fig. 1

 

 

 

 

 

 

 

coal, paper or cardboard etc.) be used in this fireplace.

 

 

 

 

 

 

 

10. The flow of combustion and ventilation air must not be

A)

Flat on wall

B)

Cross corner

C)

**Island

D)

*Room divider

obstructed in any way.

E) *Flat on wall corner

F)

Chase installation

11. Whether the fireplace is installed directly on carpeting,

 

 

 

 

 

Y)

6" minimum

 

 

 

 

 

 

 

vinyl tile or any combustible material other than wood,

Note (Fig. 1):

 

 

this fireplace must be installed on a metal or wood

** Island (C) and Room Divider (D) installation is possible

panel extending the full width and depth of the fireplace.

as long as the horizontal portion of the vent system (X)

12. This fireplace requires adequate ventilation and

does not exceed 20 feet (610cm). See details in Venting

Section.

 

 

 

 

 

 

combustion air to operate properly.

 

 

 

 

 

 

* When you install your fireplace in(D) Room divider or (E)

 

 

Flat on wall corner positions (Y), a minimum of 6 inches

 

(153mm) clearance must be maintained from the perpen-

- 3 -

dicular wall and the front of the fireplace.

Image 3
Contents BHDT36 Table of Contents Locating Your GAS Fireplace Installation and Operating InstructionsFireplace Dimensions Framing and Finishing Mantel ChartMantels Clearance to CombustiblesHearth GAS SpecificationsRemote Switch Installation GAS Line InstallationGeneral Venting Termination Clearances Vertical Sidewall Applications Vertical Sidewall Venting Graph HOW to USE the Vent GraphStep Vertical Sidewall InstallationStep Vertical Through Roof Applications Below Grade InstallationsVertical Thru the Roof Installation Crimped Ends Venting Components General Information on Assembling Twist Lock Vent Pipes 2286mm See page 21 for Venting Requirements for Snorkels Use the appropriate length of pipe section Below Grade Installations Vent Termination Storm Collar Roof Roof Flashing Storm Collar Twist Lock Venting Components Glass Frame Removal Glass CleaningGeneral Glass Information Louvre RemovalInstallation of Logs Flame Characteristics Lighting and Operating Instructions Honeywell Millivolt Valve SIT 820 Nova Millivolt Valve Replacement Parts List Replacement Parts Optional FAN KIT FK24 Optional Screen KIT Installation Optional Ceramic Refractory InstallationOptional Remote Control

BHDT36 specifications

The Vermont Casting BHDT36 is a standout in the world of gas fireplaces, known for its combination of classic design and cutting-edge technology. This direct vent gas hearth system is perfect for homeowners seeking both aesthetic appeal and efficient heating solutions.

One of the defining features of the BHDT36 is its expansive viewing area. With a large, picture-window front design, it allows for an unobstructed view of the mesmerizing flames, creating a captivating focal point in any living space. The fireplace is available in multiple finishes, which can easily complement various home décors, from rustic to modern.

The BHDT36 is equipped with Vermont Castings' innovative burner technology, which produces a radiant heat output. This design ensures that warmth circulates effectively, providing consistent heating throughout the room. The fireplace has an impressive heat output of up to 36,000 BTUs, making it suitable for substantial heating needs.

Efficiency is a priority for the BHDT36, which boasts an impressive 78% efficiency rating. This means homeowners can enjoy a significant reduction in energy costs while still enjoying the ambiance of a roaring fire. The direct vent system enhances efficiency further by drawing air from outside, ensuring that indoor air quality remains intact and that combustion is more complete.

Control options are another notable feature of the BHDT36. It comes with a remote control, enabling users to adjust the flame height and heat output with ease, without leaving the comfort of their seating area. The electronic ignition system ensures that starting the fireplace is simple and reliable, requiring minimal effort from the user.

For those who appreciate eco-friendly options, the BHDT36 can be outfitted with an optional natural gas converter, allowing for flexibility in fuel choice.

In terms of safety, the Vermont Casting BHDT36 meets all required safety standards, providing peace of mind to homeowners. The unit also features a built-in safety shutoff valve, automatically turning off the gas supply in case of an irregularity.

In summary, the Vermont Casting BHDT36 combines elegance, efficiency, and modern technology, making it an excellent choice for anyone seeking to enhance their home with a beautiful and functional gas fireplace. Its thoughtful design and features ensure that it can serve as the heart of the home for years to come.