Installation

Tools and supplies needed (Not Included): You will need the following items: two pieces of 2x stock to match your existing framing, a saw to cut the hole in the ceiling, a hammer or screw gun to attach the blocking to the existing joists, a Phillips head screw driver to attach the grille, weather strip material and low expansion spray foam sealant.

1.Cut a hole in the ceiling under where the HV1450 will be installed. Suggested methods for making the proper sized hole in the ceiling are; cut a pilot hole under where the fan will be installed. Cut toward the edge to find the joist pattern and layout the fan opening on the ceiling; OR the four corners of the opening from the attic side and draw a line between each of the four corners to layout the fan opening; OR use a stud finder to locate the joists, cut a template from the fan packaging material and use the template to layout the fan opening.The dimensions of the hole should be

no greater than 22-1/2” x14-1/2”. This will allow for the grille to cover the

WIRING: There are two

 

 

 

exposed sheetrock edges.

wires in the electrical box plus

 

 

 

2. The fan housing will fit either 16” or 24” on-center framing. Cut two

 

 

 

the ground: WHITE and

 

 

 

pieces of 2x stock (2x6 or 2x8 etc.) of the same dimension as the exist-

 

 

 

BLACK.

 

 

 

ing joists. Add these pieces of framing to form a box between the joists.

 

 

 

 

 

 

 

3. Install foam weatherstrip material (not supplied) on the top of the joists

• Connect the White wire to

 

 

 

and added framing. Caulk the joist between the ceiling and the 2x stock.

Line Neutral

 

SPECIFICATIONS:

Some types of ceilings are spaced away from the joists. Any gap between

 

• Connect the BLACK wire to

 

Voltage . . .115VAC 60Hz

the 2x’s and the ceiling should be sealed prior to final installation. Use a

 

 

Power . . . . . . . .78 Watts

low expansion spray foam sealant (not supplied).

a Switched Hot Feed or the

 

 

Airflow

. . . . .1450 CFM

4. Insert the threaded end of the hex standoffs through the hole in the

output leg of your switch.

 

 

Weight

. . . . . . . . .13 Lbs.

housing. From the backside of the housing secure each standoff with a

 

 

• Connect the ground wire to

 

Rough Opening

locknut. Place the damper on the housing with the label side facing the

 

 

. . . . . . . .14 1/2” x 22 1/2”

attic space. Pass the standoffs through the holes in the damper. Secure

the screw in the

 

 

Grille Outside Dimensions

the damper in place with a flat washer and phillips head screw. The

electrical box

 

 

. . . . . . . .15 3/4” x 25 3/4”

damper should move freely about the standoffs.

 

 

 

Grille Color . . . . . . . .White

5. Set the HV1450 on the gasket with the damper facing into the attic. The

CARE: All the motors are permanently sealed and do not require oiling. To

housing will fit the framing with the mounting flanges over lapping the joists.

6. If desired, secure the HV1450 to the top of the joists using wood screws

keep dirt, dust and debris from fan, we recommend you periodically remove

the grille from within the living space and dust the fan blades. Please remem-

(not provided). When fastening the mounting flange to the joists, care

ber to make sure that the fan is OFF before dusting the fan blades.

should be taken that all screws are tightened evenly.

TROUBLE SHOOTING: The most common problem with the HV1450 is

7. Wire the HV1450 as shown in the wiring diagram. It is recommended

wiring of the HV1450 be done by licensed electrician.

caused by incorrect wiring. Before you check anything else make sure

WHITE wire in HV1450 is connected to 115 VAC line neutral: BLACK wire

 

8. Install grille (6 screws included) on the ceiling below the fan.

is connected to a switch that will make it hot when the switch is closed.

LIMITED WARRANTY IF, WITHIN THE PERIOD OF 90 DAYS FROM DATE OF PURCHASE THE HV1450 (THE PRODUCT) IS DEFECTIVE OR MAL- FUNCTIONS IN NORMAL HOME USE, TAMARACK WILL REPAIR OR REPLACE THE HV1450 AT ITS DISCRETION WITHOUT CHARGE FOR LABOR OR MATE- RIALS. CUSTOMER IS RESPONSIBLE FOR SHIPPING CHARGES. NOTE: SOME STATE CODES REQUIRE FANS TO BE HARD WIRED. HARDWIRING THE HV1450 WILL NOT VOID WARRANTY PROVIDING THE WIRING IS PERFORMED BY A LICENSED ELECTRICIAN.

CONDITIONS, EXCLUSIONS, AND LIMITATIONS -THIS WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS, EXCLUSIONS AND LIMITATIONS. THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION, OPERATION OR MAINTENANCE THAT HAS BEEN UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS. THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT (FURNACES, SOLARIA, ETC.) ; FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER THAN TAMARACK.; FROM ABUSE, ACCIDENTAL OR SHIPPING DAMAGE, ACTS OF GOD. THIS WARRANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES, ITS TERRITORIAL POSSESSIONS AND CANADA. EXCEPT AS SET FORTH ABOVE, NO EXPRESS OR IMPLIED WAR- RANTY IS GIVEN OR AUTHORIZED BY TAMARACK. AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED. ANY WARRANTY OR MER- CHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER. MOREOVER, ANY LIABILITY OF TAMARACK FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT OF THE PRODUCT. IN NO EVENT SHALL TAMARACK BE LIABLE FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES, IRRESPECTIVE OF THE CAUSE THEREOF, OCCUR- RING EITHER DURING OR AFTER THE WARRANTY PERIOD. INCLUDING WITHOUT LIMITATION ANY DAMAGE TO ANY PART OF A BUILDING OR ITS CON- TENTS. NOTE: SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

PROOF OF PURCHASE REQUIRED.

320 Main Street • Buzzards Bay, Ma 02532

508-759-4660 / 800-222-5932 / Fax 508-759-6001

P/N HVM 1450.6

Image 2
Contents SerialNumber DateofPurchase PointofPurchase Please note the serial number, date of purchase,Switched Hot Feed or Wiring There are twoConnect the White wire to Output leg of your switch

HV1450 specifications

Tamarack Technologies has made significant strides in the field of high-voltage capacitor technology with the introduction of the HV1450 model. This cutting-edge device is engineered to meet the demands of various industrial and commercial applications, particularly where reliable power quality and voltage stability are critical.

At the core of the HV1450's appeal is its impressive voltage rating, capable of handling up to 1450 volts. This high voltage capability makes it an ideal choice for operations in environments where high power levels are common. Its robust design ensures durability and longevity, which are crucial for organizations looking to maximize operational uptime and minimize maintenance costs.

One of the standout features of the HV1450 is its advanced dielectric material. This innovative material not only enhances the capacitor's performance but also contributes to its efficiency. The use of high-quality dielectric helps to reduce energy losses and improve overall power factor. This is particularly beneficial in applications such as renewable energy systems, where efficiency and reliability are paramount.

Tamarack Technologies has incorporated advanced thermal management features into the HV1450 design. The device is equipped with a cooling system that effectively dissipates heat generated during operation. This thermal regulation not only improves the capacitor's performance but also increases its service life, making it a cost-effective investment for businesses.

Another significant characteristic of the HV1450 is its compact size. In today’s fast-paced industrial environment, space is often at a premium. The HV1450’s design prioritizes efficiency without sacrificing performance, allowing for easy integration into existing systems without the need for extensive modifications.

Furthermore, the HV1450 features robust connectivity options. It is designed to seamlessly interface with various control systems, making it easier for operators to incorporate it into their facilities. This connectivity ensures that the performance of the capacitor can be monitored in real-time, allowing for proactive maintenance and optimization of energy use.

In summary, the Tamarack Technologies HV1450 high-voltage capacitor represents a significant advancement in capacitor technology. With its high voltage rating, advanced dielectric materials, superior thermal management, compact design, and flexible connectivity options, the HV1450 is well-equipped to meet the challenges of modern industrial and commercial applications. Organizations can confidently rely on this innovative device to enhance power quality, improve efficiency, and drive operational performance.