Enviro EC-061 installation instructions

Page 2

10.EG28 or EG40: Remove the 4” (10 cm) flue collar from the unit and remove any loose sealant. Install the new Ø 4” (10 cm) by 5” (12.5 cm) flue collar provided in this kit.

Westport: Install the 4” (10 cm) adaptor into the exhaust outlet on the unit. Apply a bead of high temperature silicone.

11.Attach the flexible liner to the vent termination cap by placing a small bead of high temperature silicone on the vent termination and slide the flex liner onto the vent terminal and secure with three

(3) sheet metal screws evenly spaced.

12.Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four (4) wood screws provided. The use of non-hardening mastic should be used around the vent to ensure a watertight seal.

13.Install two (2) wire spacer around the flex pipe. Slide the horizontal section of pipe over the flexible liner. Ensure the wire spacers are positioned at either end of the pipe (refer to Figure 2 and 3).

14.Install the horizontal section of pipe through the wall thimble, ensure that this portion of pipe slides onto the vent termination cap.

15.Slide the inside finished collar over the horizontal section of pipe and secure to wall using the screw provided.

16.Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the flex pipe to the flue outlet on the appliance.

17.Stretch the flex liner to a length long enough to ensure the flex liner can be easily connected to the flue outlet of the appliance.

18.Install the remaining wire spacers over the flexible liner and install the vertical section of pipe. Ensure the wire spacers are positioned at either end of the pipe (refer to Figure 2 and 3).

19.Place a bead of high temperature silicone on the flue pipe and slide the flex liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

20.Align all straight sections of pipe, slipping all joints

together and installing with three (3) sheet metal screws evenly spaced.

21.Install the brass decorative rings around each joint making sure this decorative ring covers the sheet metal screws that secure each section of pipe together and secure to vent pipe in the slotted tab on the backside of the pipe so that the fastener would not be seen.

22.Secure the horizontal section of pipe to the inside finished collar by installing a screw in the tab on the inside finished collar. This will prevent the pipe from being disconnected at the vent terminal.

23.Light the appliance and ensure proper operation.

����

�������

Figure 2

Figure 3

Image 2
Contents KIT Components Installation InstructionsFreestanding Direct Vent Kit With Coupler Quantity DescriptionPage Part Number Option EC-061

EC-061 specifications

The Enviro EC-061 is an advanced environmental monitoring system designed to provide precise measurements and analysis for various ecological parameters. This innovative system is particularly noted for its versatility and application across several industries, including agriculture, water quality management, and air quality monitoring.

One of the main features of the Enviro EC-061 is its multi-sensor capability. The device integrates several sensors that measure temperature, humidity, soil moisture, pH levels, and other critical environmental variables. This enables users to acquire comprehensive data from a single device, thus streamlining the monitoring process. The system is equipped with high-precision sensors that ensure data accuracy, making it a reliable tool for researchers and environmentalists.

Another key characteristic of the Enviro EC-061 is its real-time data transmission functionality. Utilizing advanced wireless communication technologies, the device allows for instant data transfer to cloud-based platforms. This means users can monitor environmental conditions remotely and receive alerts about any significant changes that could warrant immediate attention. The cloud integration also facilitates data analysis, historical record-keeping, and enhanced collaboration among teams.

In terms of durability, the Enviro EC-061 is designed for harsh field conditions. It features a robust, water-resistant housing that can withstand various environmental factors, ensuring longevity and reliability. This makes it suitable for outdoor deployments, whether in agricultural fields, industrial sites, or natural reserves.

Moreover, the Enviro EC-061 comes equipped with a user-friendly interface, making it accessible for both experienced professionals and those new to environmental monitoring. The intuitive app interface allows users to customize settings, visualize data through graphs, and generate reports with ease. Additionally, the system supports integration with other smart devices, enhancing the overall monitoring experience.

In conclusion, the Enviro EC-061 is a cutting-edge environmental monitoring system characterized by its multi-sensor capabilities, real-time data transmission, durability, and user-friendly design. Its application across various sectors underscores its significance in promoting sustainable practices and proactive environmental management. By harnessing modern technologies, the Enviro EC-061 empowers users to make informed decisions based on reliable data, driving efforts to protect and enhance our ecosystems.