Zanussi ZGP 982 manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems, Check

Page 13

Wiring Diagram

L

1

A

0

2

3

4

220/240

5

6

B

N

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems

PLUG (with cover

 

 

 

 

 

 

 

 

Check

 

 

removed)

 

 

 

 

Earth Wire

(

)

Brown

Blue

 

 

Green/Yellow

 

 

Green

START

 

 

 

 

 

 

FUSE

 

 

 

 

 

 

Yellow

Isolate appliance

 

 

 

 

 

and carry out:

 

 

 

 

 

 

A: Earth Continuity

Neutral Wire

 

 

 

 

 

check.

Blue

 

 

SOCKET

(face view)

E()

NL

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

 

 

 

 

Brown

 

Green

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

Carry out:

 

Electricity supply

 

 

 

NO

YES

Carry out:

 

 

 

 

 

 

D: Resistance to

 

 

should now be

 

 

 

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 ý (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on W(Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component. It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

13

Image 13
Contents GAS HOB Important Safety Information Description of the Hob ContentsOperation Maintenance and CleaningSymptom Solution Service and Spare PartsSomething Not Working? Customer Care Department Guarantee ConditionsZanussi Service Force Midlands London & Eastanglia Engineers technical data Instructions for the InstallerOverall Dimensions Supply ConnectionsInstallation Important safety requirementsWhen the HOB is First Installed LocationFitting the hob to the worktop Gas Connection Electrical connectionsPermanent Connection This HOB Must be EarthedFault Finding Wiring DiagramPreliminary Electrical Systems CheckIgnition System / Gas Ignition Commissioning To Adjust the GAS RateConversion from Natural Gas to Customer Care