Zanussi ZGF 692, ZGF 682 manual Installation, Gas Connection, Cut Out Size, 100

Page 10

Installation

IMPORTANT: This hob must be installed by a competent person to the relevant Gas Standards.

Please, ensure that, once the hob is installed, it is easily accessible for the engineer in the event of a breakdown.

WHEN THE HOB IS FIRST INSTALLED

Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory.

Any gas installation must be carried out by a competent person.

The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.

On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.

Gas Connection

Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel or copper.

The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread).

When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation.

Ensure that the main connection pipe does not exert any strain on the hob.

It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe.

Failure to ensure the correct assembly will cause leakage of gas.

Cut Out Size

The dimensions of the cut-out are given in the diagram.

Rectangular cut-out size for hob

FO 2038

FO 0264

A)End of shaft with nut

B)Washer

C)Elbow

FO 0814

Dimensions are given in mm.

100

 

 

10

Image 10
Contents GAS Hobs Important Safety Information Contents Description of the HobHob burners Using the Wok StandOperation Burner Minimum Maximum DiameterPan Supports Maintenance and CleaningHob Top BurnersService and Spare Parts Something Not Working?This guarantee does not cover Guarantee ConditionsZanussi Guarantee conditions Customer Care DepartmentInstructions for the Installer Engineers technical dataProvision for ventilation Important safety requirementsLocation Cut Out Size InstallationGas Connection 100Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Fitting the Hob into the worktopElectrical connections Permanent ConnectionFault Finding Wiring DiagramPreliminary Electrical Systems Check Ignition System / Gas Ignition Commissioning To adjust the gas rateConversion from Natural Gas to LPG Customer Care