Zanussi ZGF 692, ZGF 682 manual Instructions for the Installer, Engineers technical data

Page 8

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

580 mm.

Depth:

510 mm.

Cut out dimensions

Width:

560 mm.

Depth:

480 mm.

Supply connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Rear Left Burner

(semi-rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner

(auxiliary)

Heat Input

1.0 kW (3412 BTU/HR)

Rear Right Burner

(semi-rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner:

(Ultra-rapid Triple-crown)

Heat Input

4.0 kW (13652 BTU/HR)

TYPE OF GAS

Characteristics

BURNER

 

ULTRA-RAPID

SEMI-RAPID

AUXILIARY

 

 

(triple

crown)

(medium)

(small)

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m3

Ws - 50.7 MJ/ m3

NOMINALTHERMAL

 

 

 

 

 

 

20 mbar

POWER

kW

4.0

1.2

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

m3/h

0.381

0.114

0.190

0.043

0.095

0.031

NOZZLEREFERENCE

146

Adjust.

96

Adjust.

70

Adjust.

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINALTHERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

4.0

1.2

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

g/h

288

86

144

32

72

24

NOZZLEREFERENCE

98

56

71

32

50

28

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

 

 

Auxiliary

28

Semi-rapid

32

Ultra-rapid (triple-crown) 56

Aeration adjustment none

APPLIANCE CLASS:

3

APPLIANCE CATEGORY:

II2H3+

APPLIANCE GAS SUPPLY:Natural gas G20 / 20mbar

8

Image 8
Contents GAS Hobs Important Safety Information Contents Description of the HobUsing the Wok Stand OperationHob burners Burner Minimum Maximum DiameterMaintenance and Cleaning Hob TopPan Supports BurnersService and Spare Parts Something Not Working?Guarantee Conditions Zanussi Guarantee conditionsThis guarantee does not cover Customer Care DepartmentInstructions for the Installer Engineers technical dataLocation Important safety requirementsProvision for ventilation Installation Gas ConnectionCut Out Size 100Building Building over a cupboard or drawerBuilding over a kitchen unit with door Fitting the Hob into the worktopElectrical connections Permanent ConnectionPreliminary Electrical Systems Check Wiring DiagramFault Finding Ignition System / Gas Ignition Conversion from Natural Gas to LPG To adjust the gas rateCommissioning Customer Care