TANDBERG 119076.02 dimensions Power Outlet Fuse, Requirements, 12/22

Page 12

TANDBERG

POWER OUTLET FUSE

Telepresence T3

REQUIREMENTS

Note! The table lists minimum fuse requirements. All electrical work must be done by electricians with local knowledge.

Note! Outside the room—adjacent to the entrance—there shall be an emergency power switch to switch off the power to the entire system and the room.

On the inside adjacent to the exit there shall be a sign with the following text:

Fire emergency switch is located on the outside of this room.

119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08

The following minimum power outlet fuse requirements apply to the TANDBERG Telepresence T3:

Item

Watt

Placement

Fuse

On/Off switch

T1 Module × 3

2400

Back wall

A

1

Presentation

60

Back wall

A

1

splitter × 2

 

 

 

 

Table power outlet × 6

2400

Back wall

B

2

TCU

400

Back wall

C

2

Table quick buttons

50

Back wall

C

2

Presentation input

5

Back wall

C

2

switch

 

 

 

 

Touch collaboration

20

Back wall

C

2

display splitter

 

 

 

 

Touch collaboration

750

Back wall

C

2

display

 

 

 

 

Document camera

300

Ceiling

D

2

T3 Ceiling mounted

750

Ceiling

D

3

lights

 

 

 

 

T3 LED Module

1000

Back- / Front wall

D

4

Total power

9335

 

 

 

PAGE 12/22

Image 12
Contents Telepresence T3 Room RequirementsSystem dimensionS 2/22Room Depth Requirements Optimal and maximal depth3/22 Telepresence T3 Minimum Room Depth Requirements 4/22Minimum Room Width Requirements 5/22Telepresence T3 Optimum and maximum Room Height 6/22Minimum Room Height Requirements 7/22Maximum Room Height 8/22Hvac Requirements 9/22Telepresence T3 10/22Acoustics Requirements 11/22Power Outlet Fuse Requirements12/22 Electronic versions Technical drawings13/22 14/22 224015/22 Customers Lan Video Lan16/22 Master Panel Light Customers Lan Video Lan17/22 18/22 19/22 20/22 Tandberg21/22 Picture center22/22 Customers Lan Video Lan