Installation Instructions
It is mandatory that all operations for the installation of this cooker be carried out by qualified and compe- tent persons to the relevant British Standards.
The manufacturer declines all responsability if safety regulations are not strictly observed.
Before the appliance is connected, check that the main fuse and the domestic installa- tion can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsabi- lity should these safety measures not be car- ried out.
This appliance meets the requirements laid down in EEC Directive No. 89/336 relating to the suppression of radio and TV interfe- rence.
Electrical Connections
The oven is designed to be connected to
Letter L - | Live terminal |
Letter N - | Neutral terminal |
- | Earth terminal |
THIS APPLIANCE MUST BE EARTHED
The cable used to connect the oven to the electrical supply should have the characteri- stics indicated in the table.
It is necessary that you install a double pole switch between the appliance and the electri- city supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in com- pliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C or above the ambient temperature.
Model | Rating | Cable Cross | Fuse |
|
| Section mm2 | Min. |
|
| and type of cable |
|
|
|
|
|
ZBM | 2,685 | 1,5 |
|
799X |
| Ho5 | 13A |
|
|
|
|
Insertion into Modular Furniture
For
Please ensure that when the appliance is installed it is easily accessible for the engi- neer in the event of a breakdown.
41