Desa CDVBN(A), CDVBP(A) installation manual 105501-01, Rev. E, 02/00

Page 36

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

COMFORT GLOW LIMITED WARRANTY

DIRECT-VENT BURNER SYSTEM AND STOVE CHASSIS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this stove and burner system to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The stove and burner system MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective stove and burner system will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

105501-01

105501 01

Rev. E

NOT A UPC

02/00

 

Image 36
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Cdvbna and Cdvbpa Cast Iron Stove and Burner SystemProduct Features Product Identification Local CodesGlossary Terms OperationPRE-INSTALLATION Preparation Location and Space RequirementsCast Iron Stove and DIRECT-VENT Burner System Assembly Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Bolt Stop Adjusting Nut Catch BoltDoor Screw Burner System Bolt Bottom Stove Unit LegInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersBlack White Wire Blower Blue Green Rear Cover Wire Blower Ground WireInstalling Rear Cover Firebox Installed In Cast Iron Stove BodyGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination SnorkelSnorkel Minimum Adequate drainage Female Locking Lugs Male Slots Rigid Vent Pipe Vent Opening Combustible WallApply Mastic to All Four Sides Wood Screw Vent Cap Cut Vinyl SidingHorizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationRoof Flashing Wall Strap Elbow Ceiling FirestopCathedral Ceiling Installation If area above is a room, install firestop above framed holeLevel Cathedral ceiling support box Vertical Termination Configurations Restrictor intoCollar of burner System as shownHigh Altitude Installation Parts Lists for Venting Kits and ComponentsComfort Glow Rigid Venting Rvkbk Kit ShownStove DIRECT-VENT Burner System Installation Installing GAS Piping to STOVE/BURNER System LocationInstallation Items Needed Check GAS TypeConnecting STOVE/ Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Flare Fitting on Control Valve Manual Shutoff ValvePressure Testing Burner System Gas Connections Open Manual Shutoff Valve ClosedGas Valve Manual Propane Shutoff LP Supply Valve TankInstalling Remote Receiver Installing LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Stove with Burner System Lighting InstructionsOptional Remote Operation Thermostat Control OperationCghrc Series Operation Cghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Burner Flame PatternCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramService Hints Technical ServiceSpecifications AccessoriesReceiver and HAND-HELD Remote Control KIT Cghrc Series Manual Blower KIT GA3750Illustrated Parts Breakdown Cdvbna CdvbpaParts List KEY Part Number Description QTYCdvbna and Cdvbpa Stove Chassis Cisc CisgKEY Part Description QTY 105501-01 Rev. E02/00

CDVBP(A), CDVBN(A), CDVBP(A) specifications

Desa CDVBN(A), CDVBP(A), and CDVBP(A) are innovative and cutting-edge technological platforms designed to enhance communication and operational efficiency in various sectors, including business, education, and public services. Each of these platforms boasts unique features and characteristics that make them stand out in their respective fields.

Desa CDVBN(A) is known for its robust hybrid integration capabilities. It allows organizations to seamlessly connect on-premises systems with cloud applications, thereby enabling hybrid workflows and ensuring data consistency across different platforms. One of its main features is a versatile API management toolkit that facilitates the smooth exchange of information between disparate systems. This capability is especially beneficial for organizations looking to modernize their IT infrastructure without entirely discarding legacy systems. Furthermore, its user-friendly interface encourages ease of adoption among non-technical users.

On the other hand, Desa CDVBP(A) focuses primarily on business process optimization. It introduces advanced automation features that streamline repetitive tasks, reduce operational costs, and improve turnaround times. Equipped with machine learning algorithms, CDVBP(A) learns from user interactions to optimize workflows dynamically. This platform’s main selling point is its extensive analytics capabilities, providing organizations with valuable insights into productivity patterns, resource utilization, and areas for potential improvement. Its customizable dashboard allows users to visualize data effectively, thereby empowering informed decision-making.

Desa CDVBP(A), while sharing similarities with its counterpart, takes a more specialized approach aimed at enhancing collaborative efforts within teams. It integrates features such as real-time messaging, file sharing, and project management tools, creating a centralized space where team members can interact and collaborate seamlessly. The platform leverages cloud technology to ensure accessibility from anywhere, making it an ideal solution for remote teams. Additionally, it offers secure data encryption and compliance features, ensuring that sensitive information is protected against unauthorized access.

In summary, Desa CDVBN(A), CDVBP(A), and CDVBP(A) exemplify the future of communication and operational efficiency. Each platform serves distinct yet complementary roles, ranging from hybrid integration and business process optimization to teamwork enhancement. By embracing these technologies, organizations can position themselves competitively in an increasingly digital landscape, improving not only their internal operations but also their overall service delivery.