Garland SRC operation manual Dimensions and Specifications, Product MSR16 Mrsc

Page 4

DIMENSIONS AND SPECIFICATIONS

34"

[864mm]

17 61/64" [456mm]

165/16"

[414mm]

16 13/16" [427mm]

20 1/4"

[514mm]

 

PRODUCT

 

MSR16

MRSC

 

 

 

 

 

 

 

 

 

 

Width: In(mm)

 

34(864)

 

34(864)

 

 

 

 

 

 

 

 

 

 

Depth: In(mm)

 

20-1/4(514)

 

20-1/4(514

 

 

 

 

 

 

 

 

 

 

Height: In(mm)

 

35-5/8(965)

 

17(432)

 

 

INPUT:BTU/hr(kw)(Natural Gas)

 

28,000 (8.20)

 

28,000 (8.20)

 

 

 

 

 

 

 

 

 

 

Shipping Wt:(LB/KG)

 

170/78

 

135/61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION NOTES

 

 

 

Combustible Wall Clearances ¹

 

Entry Clearances

 

Operating Pressure

 

 

 

 

 

 

 

Sides: 0"

 

Crated: 26-3/4" (680mm)

 

Natural: 6" WC (15mbar)

 

Back: 0"

 

Uncrated: 21" (533mm)

 

Propane: 11" WC (28mbar)

 

 

 

 

 

 

 

 

¹ For instillations in non-combustible locations only.

NOTE: Data applies only to North America

Gas input ratings shown here are for installations up to 2,000 ft. (610m) above seal level. Specify altitudes over 2,000 ft.

Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire Protection Association's standard NFPA96. “Vapor Removal from Cooking equipment”

(for North American only)

Please specify gas type when ordering.

Page 4

Part # 1382684 Rev. 1 (02/11/11)

Image 4
Contents Master Series INFRA-RED Important Information Table of Contents Dimensions and Specifications Product MSR16 MrscIntroduction Suffix DefinitionsProduct application Rating PlateInstallation Gas Supply Testing And AdjustmentsVentilation and Air Supply Operation Main burner Adjustments Safety PrecautionsAll Models Burner Ignition Burn off PeriodMaintenance and Cleaning Exterior CleaningDaily MonthlySafety ServicingPage Page Réparations Les .d’installation conditions des fonction en SécuritéRéparation Réglementation la selonNettoyage ET Entretien Extérieur NettoyageMois Chaque Jour ChaqueSécurité De Précautions ’énergie Économies’utilisation Suggestions Brûlage de PériodeFonctionnement ’allumage InstructionsPrincipal Brûleur du Fonctionnement Veilleuses des D’allumage Instructions MS M, ModèlesAllumer .gaz en d’alimentation principal robinet le Ouvrir Réglages Et Essais’eau colonne FonctionnementInstallation EmplacementLégale Réglementation DégagementsSignalétique Plaque Suffixes des Définitions13,000 1mm.1 14,000 47F BTU/h Orifice Calorifique DébitSpécifications ET Dimensions Mbar 28 CE po 11 Propane Mm 533 po 21 Déballé Po 0 ArrièrePo 0 Côtés 135/61 170/78 LB/KG d’expédition Pds 20.8 28,000Installation Matières DES TableSécurité RéparationImportantes Informations Inc Industries, Commercial Garland