PREPARE THE CABINET
1.Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rear wall. Put a thick, protective covering over cooktops,
2.Determine and clearly mark with a pencil the center line of the cabinet on the wall and on the underside of the cabinet where the rangehood will be installed.
3.Determine the proper cutouts for the ductwork. Make all necessary cuts in the walls or cabinets for the ductwork. Install the ductwork before mounting the rangehood.
4.If the cabinet bottom is recessed, wood filler strips need to be installed.
5.Drill four 3/16" clearance holes for hood mounting screws.
FIGURE 4
6. Cut a 6 1/2" diameter hole in cabinet bottom as shown.
FIGURE 5
7.Determine and make the proper cutout for the Power Supply Cable. Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply Cable through the wall or cabinet. DO NOT turn on the power until installation is complete. Use caulking to seal around the wire opening.
FIGURE 6
8.Remove the grease filters USING TWO HANDS by pulling the knob out and turning to the left.
9.Remove the terminal box cover (located on the back wall of the hood. Remove the power supply cable knockout using a
10.Attach damper to exhaust opening on top of the range- hood using the two small screws from the hardware pack- age.
INSTALL THE RANGEHOOD
1.Place the rangehood mounting screws close to the holes in the cabinet bottom.
2.Lift rangehood into place while feeding wiring through strain relief.
3.Insert the screws through the clearance holes and start them into the rangehood.
4.Connect the vent system to the rangehood and seal all joints with duct tape.
5.Connect the Power Supply Cable to the rangehood. Attach the White lead of the power supply to the White lead of the rangehood with a
6.Install the grease filters using two hands by first pulling
and turning the knob to the left so that the locking lever does not protrude from the filter (as in FIGURE 7). Insert the op- posite end of the filter into the retaining channel. Insert the knob end next, then turn knob to the right to lock the filter into place.
FIGURE 7
7.Turn the power supply on. Turn on blower and lights. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.
Version 08/06 - Page 6