Faber AXIA ISOLA installation instructions Venting Requirements, Electrical Requirements

Page 2

VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. If it is used, each foot of flexible ductwork used is equivalent to two feet of straight metal ductwork when calculating the ductrun length. Thus, a flexible elbow equals two standard elbows.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. For best results, remote blowers should transition to 9" round duct as soon as possible. If small ducting is used, it should be transition to 9" round as soon as possible.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

!WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment.

THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- essary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:InstallationWorkAndElectricalWiringMust Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire ProtectionAssociation (NFPA), and theAmerican Society for Heating, Refrigeration andAir Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not dam- age electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

!WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

Failure to follow electrical requirements may result in a fire.

Version 02/02 - Page 2

Image 2
Contents Lisez Bien Cette Fiche Avant Dinstaller LA Hotte Read and Save These InstructionsVenting Requirements Electrical RequirementsRèglements Dévacuation Fiche Technique ÉlectriqueUnpack the Rangehood Plan the InstallationCalculate the Ductrun Length Attaching the SupportAttach the Support For ductless installationsInstall the Canopy Turn the power supply on. Turn on blower Warranty & Service USE and Care InformationDéballer LA Hotte Installation DU SupportCalcul DE LA Longueur DU Conduit Pour les installations sans conduit Installation DE LA HotteAvertissement Garantie ET Service Utilisation ET Entretien

AXIA ISOLA specifications

The Faber AXIA ISOLA is a sophisticated kitchen hood that embodies the perfect blend of style, innovation, and functionality. Designed with the modern kitchen in mind, this range hood offers exceptional performance and aesthetics, making it an ideal choice for those who value both form and function in their cooking space.

One of the standout features of the AXIA ISOLA is its sleek, contemporary design. It has a minimalist aesthetic that complements various kitchen styles, from ultra-modern to traditional. Available in different finishes such as stainless steel or glass, the AXIA ISOLA seamlessly integrates into any kitchen décor, serving as both a powerful ventilation solution and an eye-catching centerpiece.

The AXIA ISOLA employs cutting-edge technologies that enhance its effectiveness. One such technology is the high-performance motor, which ensures efficient air extraction, eliminating smoke, odors, and pollutants from the kitchen environment. Additionally, the hood incorporates advanced noise-reduction technologies, allowing for quiet operation even at high speeds. This makes it perfect for open concept kitchens, where cooking and socializing often happen simultaneously.

Another notable characteristic of the Faber AXIA ISOLA is its versatile installation options. Designed for both ducted and recirculating installations, the hood offers flexibility depending on kitchen layout and planning. This allows homeowners to maximize their kitchen's functionality without compromising on design.

The AXIA ISOLA features intuitive controls, often equipped with touch-sensitive buttons or remote-control functionality, allowing users to easily adjust settings from a distance. Additionally, integrated LED lighting illuminates the cooking area effectively, enhancing visibility while also being energy-efficient.

Cleaning and maintenance are also simplified, thanks to its stainless-steel construction and dishwasher-safe filters. These features reduce the effort needed to keep the hood looking and operating like new.

Overall, the Faber AXIA ISOLA is more than just a kitchen hood; it is a combination of elegance, innovation, and practicality. Perfect for culinary enthusiasts and home cooks alike, it elevates the cooking experience while ensuring a clean and fresh kitchen environment. With its advanced technologies and stylish design, the AXIA ISOLA is an investment in both the functionality and aesthetics of any modern kitchen.