3.After determining the location of the venting system termination point (see Diagram A), cut a square hole through the wall 1" larger than the outer pipe diameter of the power venter. Mount the power venter through the wall, keeping the outer pipe centered in the hole. (See Figure 3) Fasten the power venter to the outside wall with appropriate fasteners. Seal the edges of the power venter base plate to the wall with a high temperature silicone sealant. DO NOT enclose the spaced plates on the power venter body. This will result in reduced cooling of the power venter body. Wood or vinyl siding should be cut so that the unit mounts directly on the wall board to provide a stable support. If the siding is greater than 1/2" thick use a spacer plate or board behind the power venter mounting plate. (See Figure 2)

NOTE: If mounting the power venter though a combustible wall material and the flue gas temperature is above 400°F at the power venter inlet, line the square hole with a piece of corrosion resistant sheet metal or non-combustible material. The liner piece should be the same width as the wall section. (See Figure 3) The power venter has a maximum flue gas temperature of 550°F at the venter inlet. For installation in wall thicknesses over 8 inches, use an SWG Series Though Wall Extension Kit, Model PEK.

2.Remove the end pipe cover screws on the sides of the outside pipe and remove end pipe cover. Then mount the backing plate over the outer pipe and route the flexible conduit and pressure switch tube (if applicable) through the holes provided in the backing plate. Fasten the backing plate to the inside wall with appropriate fasteners. (See Figure 4) Re-install end pipe cover and screws.

Page 5

Diagram A

Figure 2

Figure 3

Figure 4

Image 5
Contents Typical Venting System Components ContentsOptional System Components General System InformationControl Kits Installation Safety InstructionsOIL GAS Maximum Equivalent Feet of Vent Pipe For 3 *RATIOS d/D Diagram a SWG/SWGII Double Pipe System Single Pipe SystemAIR Flow Adjustments Class B and Class L Double Wall Vent Pipe InstallationWiring Maintenance General Installation InspectionModel Repair Motor Assembly Blower Wheel Replacement PartsSWG/SWGII-4HD SWG/SWGII-5Installation Date Initial Burner and Venting System Operational InformationFor GAS Fired Equipment For OIL Fired Equipment46139100 Rev J 05/01

SWGII, SWG, SWG Stainless specifications

Field Controls has established itself as a leader in advanced air quality control solutions, and their SWGII and SWG series, including SWG Stainless, exemplify cutting-edge technology in air purification and ventilation systems. These systems are designed to meet the demanding needs of commercial and residential environments, ensuring optimal air quality and energy efficiency.

One of the standout features of the SWGII is its robust design. Built with high-quality stainless steel, this model is resistant to corrosion, making it an excellent choice for applications in areas with high humidity or potential exposure to moisture. The stainless steel construction not only enhances durability but also provides a sleek, professional appearance that suits various installations.

The SWGII utilizes advanced ultraviolet (UV) light technology to eliminate harmful pathogens such as bacteria, mold, and viruses from the air. By integrating UV-C light within the system, it effectively reduces the microbial load, providing a healthier environment without the use of harmful chemicals. This makes it particularly beneficial for hospitals, schools, and other establishments that prioritize cleanliness and hygiene.

In terms of efficiency, the SWG series is engineered to work seamlessly with existing HVAC systems, enhancing air circulation while minimizing energy consumption. The models are equipped with features that allow for variable airflow adjustments, ensuring optimal performance depending on the setting. This adaptability not only improves user comfort but also contributes to significant energy savings over time.

Another notable characteristic of the SWG and SWG Stainless is their user-friendly interface and straightforward installation process. Field Controls has prioritized ease of use, allowing for quick setup and minimal maintenance requirements. This is particularly advantageous for contractors and end-users alike, as it reduces downtime and maintenance costs.

Additionally, the SWG series is designed with environmental considerations in mind. By reducing reliance on traditional methods of air purification and promoting energy efficiency, these systems align with contemporary sustainability practices, making them an ideal choice for eco-conscious consumers and businesses.

In summary, Field Controls SWGII, SWG Stainless, and the broader SWG series represent a significant leap in air quality technology, combining durability, efficiency, and health-focused features into a single system. With their advanced UV technology, robust construction, and user-friendly design, these units are transforming the way we think about indoor air quality. They stand as a testament to Field Controls’ commitment to innovation and their mission to create healthier living and working environments.