Faber 36 Venting Requirements, Ductwork, Electrical Requirements, For residential use only

Page 2

VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. If it is used, each foot of flexible ductwork used is equivalent to two feet of straight metal ductwork when calculating the ductrun length. Thus, a flexible elbow equals two standard elbows.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO

TO PAGE 5.

WARNING - To Reduce The Risk Of Fire, Use Only Metal

Ductwork.

Cold Weather installations

An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house.

!WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

For residential use only.

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- essary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING-TOREDUCETHE RISK OF FIREORELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:InstallationWorkAndElectricalWiringMust Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire ProtectionAssociation (NFPA), and theAmerican Society for Heating, Refrigeration andAir Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not dam- age electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

!WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

Failure to follow electrical requirements may result in a fire.

Version 04/08 - Page 2

Image 2
Contents Lisez Bien Cette Fiche Avant Dinstaller LA Hotte Read and Save These InstructionsElectrical Requirements Venting RequirementsDuctwork For residential use onlyFiche Technique Électrique Installations pour régions à climat froidRèglements Dévacuation Uniquement pour usage menagerHigh Backsplash/Dosseret 30 po Replacement Charcoal Filters/ Filtres au CharbonHigh Backsplash/Dosseret 24 po Ductless Conversion Kit Kit Pour Conversion Du ConduitCalculate the Ductrun Length Plan the InstallationRangehood Assembly Prepare the Wall Are Securely Fastened to the WallFor Ductless Installations Item R in FigureUSE and Care Information Faber Warranty & Service Save for Your Records AVERTISSEMENT! Avant DE Faire Plan D’INSTALLATIONPlan DE L’INSTALLATION Calcul DE Longueur DU Conduit Assemblage DE LA HottePréparation DU MUR Installation DE LA HotteSont Bien Installées AU MUR Installations Sans Conduit De chaque côté du ventilateurUtilisation ET Entretien Faber Garantie et service

36 specifications

The Faber 36 is a cutting-edge device designed for efficiency and performance in modern applications. Renowned for its sleek design and advanced technology, the Faber 36 stands out in the market for its unique features that cater to both professionals and tech enthusiasts.

One of the main features of the Faber 36 is its powerful processing capability. It is equipped with a high-speed processor, allowing it to handle complex tasks effortlessly. This makes it ideal for activities such as video editing, gaming, and data analysis. The device boasts a generous amount of RAM, ensuring seamless multitasking without lag, enhancing overall productivity.

Another significant characteristic of the Faber 36 is its display technology. The device features a vibrant, high-resolution screen that delivers sharp images and vivid colors. This makes it perfect for content creators who require accurate color representation for their projects. Additionally, the display is designed to reduce eye strain, making it comfortable for prolonged use.

In terms of connectivity, the Faber 36 does not disappoint. It includes multiple ports for various peripherals, including USB-C and HDMI, enabling users to connect external devices easily. Wi-Fi 6 technology ensures fast and reliable internet connectivity, making it suitable for online gaming, streaming, and cloud-based applications.

The Faber 36 also prioritizes user experience with its intuitive interface. Designed for ease of use, the device features a customizable dashboard that allows users to access their favorite applications and tools quickly. The integration of advanced AI technology enhances functionality, providing smart suggestions and automating routine tasks, thus saving valuable time.

Battery life is another area where the Faber 36 excels. Equipped with an efficient power management system, it offers extended usage on a single charge, making it perfect for users on the go. Fast charging capabilities ensure minimal downtime, allowing users to stay productive throughout the day.

Lastly, Faber prioritizes sustainability, with the Faber 36 constructed from eco-friendly materials. This commitment to environmental responsibility reflects in its design and packaging, making it a choice for consumers who value ecological impact.

In summary, the Faber 36 combines power, efficiency, and sustainability into a single device. With its robust processing capabilities, vibrant display, comprehensive connectivity options, intuitive interface, long battery life, and eco-friendly design, it caters to the diverse needs of users, making it a standout choice in today’s technology landscape.