Sound Performance Lab 2710 manual Hook Up, Scope Of Delivery, Placement, Rack Mounting

Page 7

Hook Up

Scope Of Delivery

The RackPack frame including all blind panels and the front panel (if modules are not fit- ted already). Please note that all modules are shipped without the aluminum front panel.

You need it when you fit a module into the frame. Therefore make sure that you handle the aluminum front panels with the same care and prudence as any other unit surface. All

screws holding front and rear blind and front panels are needed for the fitting of modules. Two additional screws are shipped with every module.

The external power supply including the cable for connection to RackPack

The AC power cord to feed the IEC-spec, 3-prong connector

This manual

4-mm-Allen key required for the fitting of the module

Please save the original packaging. In service cases the original packaging ensures a safe shipping and handling. It is also useful for your own transports if you don’t use a special housing or rack.

Placement

Place the unit on a level and stable surface. The unit’s enclosure is EMC-safe and effec- tively shielded against HF interference. Nonetheless, you should carefully consider where you place the unit to avoid electrical disturbances. It should be positioned so that you can easily reach it, but there are other considerations. Try not to place it near heat sources or in direct sunlight, and avoid exposure to vibrations, dust, heat, cold or moisture. It should also be kept away from transformers, motors, power amplifiers and digital processors. Always ensure sufficient air circulation by keeping a distance of 4-5 cm/2 inches to other units and to the sides of the unit.

Rack Mounting

Be sure that both above and below the machine you maintain a distance of 4-5 cm/2 inches in order to eliminate electromagnetic or high frequency interference from other equipment.

Moreover, this will ensure adequate air circulation to prevent overheating. Do NOT locate other machines that produce excessive heat below the unit. The rear side of the machine should be properly supported – especially when transport is involved.

Placement Of The External Power Supply

Do not place the external power supply on top of the RackPack. Place the external power supply on a level and stable surface only. We recommend a distance of at least 50 cm/20 inches to avoid any interferences between the external power supply and the RackPack frame or other devices.

Choose a place that is easily accessible so that you can switch off the external power supply quickly in case of an emergency.

Please mind the notes under “Power Connection” and “On And Off” on the next page.

RackPack

7

Image 7
Contents Manual Version 1.0 8 /2007 Designer Wolfgang Neumann Manual RackPack, ModelContents Important Safety Information Symbols And Notes Freedom As a Matter Of Principle IntroductionRackPack RackPack ModulesScope Of Delivery PlacementPlacement Of The External Power Supply Hook UpOn And Off Power ConnectionSignal Connections Air CirculationDPNTPVOEQFSGPSNBODFMBCXXX Rear PanelTop View Please NoteFront View Rear ViewStep Fitting Modules .0%6-& .0%6-& .0%6-& Link Cable Installation Top ViewExternal Power Supply Guarantee Dimensions & WeightManual RackPack