Sound Performance Lab 9629 Specifications, Input & Output, Measurements, Power Supply, Dimensions

Page 8

Specifications

Input & Output

Instrumentation amplifier, electronically balanced (differential), transformerless

Nominal input level

+6 dB

Input impedance

= 22 kOhms

Output impedance

< 600 Ohms

Max. input level

+24 dBu

Max. output level

+22,4 dBu

Minimum load ohms

600 Ohms

Hard Bypass Relay / Power Fail Safety

 

Measurements

Frequency response

20 Hz - 50 kHz

(50 kHz = -3 dB)

 

CCMR (common mode rejection)

-80 dBu @1kHz

THD & N

0,002% @ 1kHz

S/N CCIR 468-3

-93 dBu

S/N A-weightened

-106 dBu

Power Supply

Torroidal transformer

15 VA

Fuse

200 mA

Ground-Lift switch

yes

Voltage selector

yes

Dimensions

Housing

............................................................... Standard EIA 19"/1U

 

... 482 x 44 x 237 mm

Weight

3,4 kg

Note: 0 dBu = 0.775 V. Subject to change without notice.

8

Image 8
Contents Manual Manual Auto Dynamic De-Esser ModellContents ForewordInstallation & Security Advices IntroductionHow do traditional De-Essers work? How does SPL’s Auto Dynamic De-Esser work?Connections Rear panelControl Elements Reduction Auto-ThresholdPower Supply Male/FemaleSpecifications Power SupplyDimensions Input & OutputWarranty