Technical Data
Heating elements rating |
| Dimensions of recess |
| |
Circular heating element | 2.08 kW | Height | 580 mm. | |
Inner Grill element | 1.82 kW | Width | ||
Grill element | 1.83 kW | Depth | 550 mm. | |
OvenLight | 15 W | Dimensions of the oven cavity | ||
Cooling Fan | 25 W | |||
ConvectionFan | 30 W | Height | 320 mm. | |
|
| |||
Total Rating | 2.15 kW | Width | 420 mm. | |
Depth | 390 mm. | |||
|
| |||
|
| Oven capacity | 53.2 litres |
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Liveterminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
For Uk use only
Connection | Min. size | Cable / flex | Fuse |
via | Cable/flex | type |
|
|
|
|
|
• 13 A socket | 2.5 mm2 | 3 core | 13 A |
outlet |
| butyl | min. |
• 13 A |
| insulated |
|
spur box |
|
|
|
|
|
|
|
• Cooker | 2.5 mm2 | PVC/PVC |
|
Control |
| twin and | 20 A |
Circuit |
| earth |
|
|
|
|
|
For Europe use only
Min. size Cable/flex | Cable / flex type | Fuse |
|
|
|
1.5 mm2 | H07 | 13 A |
| H05 |
|
| H05 |
|
| H05 |
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
Themanufacturerdisclaimsanyresponsibilityshould these safety measures not be carried out.
16