Toastmaster TMGM24 Exhaust Canopy, Leveling Unit, GAS Piping, GAS Pressure Regulator, Propane GAS

Page 5

EXHAUST CANOPY

It is essential that facilities be provided over the griddle to carry off fumes and gases. However, the unit should not be directly connected to a flue or stack.

LEVELING UNIT

This griddle is supplied with (4) feet which must be screwed into the legs attached to the body. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" (43.75mm) for accurate and perfect lineup with other units.

CAUTION DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of LP gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage the valve and affect its operation. When installing this appliance, all pipe and fittings must be free from loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe at the rear of the unit. The gas supply line is then connected to it. It is shipped set for 6" (15.24cm) water column manifold pressure for use with natural gas.

MANUAL SHUT-OFF VALVE

A manual shut-off valve should be installed upstream from the union and within 6 feet (1.829m) of this appliance.

PROPANE GAS

This griddle is equipped with fixed orifice hoods and is shipped from the factory for use on natural gas. To convert to propane gas, install the burner orifice hoods, located in the grease drawer, as follows:

1.Remove front panel by removing screws located on the front and the bottom.

2.Remove the burner(s) from the orifice hood(s). This is accomplished by removing the burner mounting screw(s) and sliding the burner(s) off the hood(s).

3.Remove natural gas orifice hood(s) and install the propane hood(s) furnished.

4.Reinstall burner(s).

Note: TMGM & TMGT units use a #47 drill orifice for natural gas and a #55 drill orifice for propane.

5.Reinstall front panel.

6.Remove the slotted, or hex-threaded, plug from the pressure regulator. Invert the plug and re- install. The letters "LP" should now be visible on the plug. The regulator is now set for 10" (25.4cm) water column.

7.Set manifold pressure to 10" (25.4cm) water column. A 1/8" pipe plug on the supply pipe can be removed for attaching a pressure gauge.

CONNECTING GAS SUPPLY LINE

The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.

CHECKING FOR GAS LEAKS

Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage. Matches, candle flame, or other sources of ignition shall not be used for this purpose. Check entire piping system for leaks.

Image 5
Contents GAS Griddle Retain this Manual for Future Reference Safety SymbolSpecifications Gas Griddle AIR Supply ClearanceExhaust Canopy Connecting GAS Supply LineLeveling Unit GAS PipingBurner Adjustment Models Tmgt Burner Adjustment Models TmgmLighting Instructions Pilot Light RegulationGriddle Care NON-CHROMIUM Areas Grease PANModel TMGM24, TMGT24 26 29 Parts List Qty Description Warranty Statement Page Page Seulement MD Modèles Brûleurs DES Fonctionnement Garde EN MiseSeulement Tmgt Modèles Brûleurs DES Ajustement GAZ DU Provision LA DE Ligne Reliant LAGAZ DU Pression LA DE Régulateur LE Manuel D’ARRÊT RobinetGAZ DE Canalisation Niveau À Mise DE Unité’APPAREIL DE L’ÉCART À Combustible Tout Tenez Garde EN Mise ’INSTALLATION Générales DonnéesAvis Future Référence Pour Manuel CE Conservez Réparations ET EntretienGAZ a Grils