Installing the hood 5
•Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save installation instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through metal electrical conduit.
Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 – latest edition”, or CSA Standards
A U.L.- or
Copies of the standards listed may be obtained from:
*National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
**CSA International 8501 East Pleasant Valley Road Cleveland, Ohio
Power requirement:
120V~, 60Hz, 15 or 20A branch circuit
Intended use
•Your range hood is intended for exhaust operation only. This range hood is not recommended to be used over indoor grills. Do not use it to exhaust hazardous or explosive materials or vapors.
Parts supplied
No. Part |
| Qty. |
1 | Range hood | 1 |
2 | Glass cover | 1 |
|
| Upper and lower | 1 |
3 |
| + | |
| chimney | ||
|
| 1 | |
|
|
| |
4 |
| Upper bracket | 1 |
5 |
| Lower bracket | 1 |
6 |
| Collar | 1 |
|
| Recirculation kit |
|
7 |
| (optional | 1 |
| accessories) | ||
|
|
| |
|
|
| |
|
| Bulb |
|
8 |
| 20W, 120V~, GU10 | 2 |
|
|
| |
9 |
| Bolt, rubber | 4 |
| washer, washer | sets | |
|
| ||
10 |
| Long screw | 8 |
| (4mm x 32mm) | ||
|
|
| |
11 |
| Wall plug | 8 |
12 |
| Short screw | 4 |
| (4mm x 12mm) | ||
|
|
| |
13 |
| Allen key | 1 |
|
| Wood screw |
|
14 |
| (4mm x 50mm) | 4 |
| Short screw | ||
|
|
| |
|
| (3.5mmx8mm) |
|
15 |
| Short screw | 2 |
| (3.5mmx8mm) | ||
|
|
| |
|
| 10’ extension |
|
|
| chimney kit |
|
16 |
| (optional | 1 |
|
| accessories) |
|
|
| FHW10X60LS |
|
17 | Template | Assembly template | 1 |
(stencilled) | (stencilled) | ||
|
|
|
GB