DeLonghi DEGLSC 24 SS warranty Wire Conduit Installation

Page 11

3-Wire Conduit Installation

(See Figures 2.1, 2.7, 2.8 and 2.9)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (2.7).

3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 2.8).

4.Feed 3/4” (1.90 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp (fig. 2.9).

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.

7.Plug washers and tighten nuts securely.

Do not remove Ground strap.

8.Assemble the Terminal Block Access Plate.

4-Wire Conduit Installation

(See Figures 2.1, 2.7, 2.8 and 2.10)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (fig. 2.7).

3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in figure 2.8).

4.Feed 3/4” (1.90 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp (fig. 2.10).

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Remove the Ground Strap from the frame of range and ter- minal by removing its screw and cutting it as shown in fig- ure 2.10.

7.Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires

must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.

8.Plug washers and tighten nuts securely.

9.Assemble the Terminal Block Access Plate.

Fig. 2.7

Bracket

Fixing Screws

Bracket

Strain Relief

Fig. 2.8

Opening For

Electrical

Connection

Fixing Screws

Conduit

Bracket

Fig. 2.9

Terminal Block

Ground strap

Neutral Wire

Power Wires

Conduit Clamp

 

Conduit

Conduit

Bracket

 

 

Fig. 2.10

Terminal Block

Cut Ground Strap

 

Grounding Wire

Neutral Wire

 

Power Wires

 

Conduit Clamp

Grounding Screw

 

 

Conduit

Conduit

Bracket

11

 

Image 11
Contents Electric Range ALL Ranges can TIP Installation Instructions Electrical Grounding Instructions Replacement PartsElectric Connection Proximity to Side CabinetsAssembling the Backguard It is mandatory to install the backguardLevelling the Range ANTI-TIP Stability Device Installation Instructions Electrical Connection with Conduit Electrical Connection with Power Cord Electrical Requirements Wire Flat Power Cord Installation Wire Power Cord Installation Wire Conduit Installation 120 Wiring DiagramPage Page Page Cod ß3