Danby DER2009W installation instructions For conduit installations only

Page 39

For conduit installations only:

WARNING: Electrical Shock Hazard

Disconnect power before servicing.

Electrically grand range.

Use 8-gauge copper wire or 6-gauge

Failure to follow these instructions can

 

aluminum wire.

 

result in death, fire or electrical shock.

Purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block.

Important: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the range wiring cover.

3-WIRE CONDUIT INSTALLATION

Use this method only if local codes permit connecting ground conductor to neutral supply wire.

Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will then be accessible.

Remove the knockout located on bracket directly below the terminal block as needed for conduit connection. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.

Assemble a U.L.-listed conduit connector in the opening.

Strip the insulation back 1 inch from the end of each wire.

Use only ring terminals to connect the power supply.

Allow enough slack in the wire to easily attach the wiring terminal block.

Use a ¼” nut driver and remove the hex washer head nuts from the terminal block.

Connect the line wires (1 and 2) to the outside terminals and the neutral wire to the center terminal. Securely tighten nuts for proper electrical connection. Do not remove the ground strap.

Tighten the locking ring of the conduit connector.

Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire cover and main back.

4- WIRE CONDUIT INSTALLATION

Use this method for new installations and whenever 4-conductor installation is required.

Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will then be accessible.

Remove the knockout located on bracket directly below the terminal block as needed for conduit connection. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.

Assemble a U.L.-listed conduit connector in the opening.

Strip the insulation back 1 inch from the end of each wire.

Use only ring terminals to connect the power supply.

Allow enough slack in the wire to easily attach the wiring terminal block.

Remove the ground-link screw from the range frame. Save the ground-link screw. Bend the ground link away from the range so that it does not contact the range.

Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

Use a ¼” nut driver and remove the hex washer head nuts from the terminal block.

Connect the line wires (1 and 2) to the outside terminals and the neutral wire to the center terminal. Securely tighten nuts for proper electrical connection.

Tighten the locking ring of the conduit connector.

Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire cover and main back.

Image 39
Contents Mise EN Garde Precaución Please do this NOW WelcomeImportant Safety Information Proper InstallationBefore First USE Important Safegaurds Important Safety Information cont’dOven Cooking Safegaurds cont’dEnergy Saving Tips Surface CookingInstallation Instructions Leveling a Free Standing RangeElectrical Remember Operating InstructionsSurface CookingFood Rack Position OvenNumber of Pans Position on Rack Programmed Oven Cooking To Broil at Maximum Temperature Regular BroilTo Broil at Controlled Temperatures Auto Vari Broil BroilingNot Immerse Element in Water Care and CleaningProblem Possible Cause Solution TroubleshootingNuméro de Modèle Numéo de Type Numéro de Serie Date d’achat BienvenueInstallation Correcte Consignes DE Sécurité ImportantesAvant LE Premier Usage Mises EN Garde Importantes Consignes DE Sécurité Importantes suiteCuisson au dessus de la cuisinière LES Suggestions Déconomie DénergieMises EN Garde Importantes suiteInstructions Dinstallation Mise À Niveau D’UNE Cuisinière AutostableÉlectriques Consignes D’UTILISATION RappelQuelle batterie de cuisine utiliser Cuisson Dans LA CuisinièreNombre D’ Ustensiles Position SUR LA Grille Avant de commencer la cuisson LA Cuisson AUGrilloir Cuisson au four préprogramméeChauffant Dans L’EAU Soins ET EntretienProbleme Cause Probable Solution Dépannage800-26 Sírvase Realizar LO Siguiente Ahora BienvenidaInformación Importante DE Seguridad Antes DE Utiliza PrimeroInstalación Apropiada Importante Para LA Seguridad Importante Para LA Seguridad cont’dPara Ahorrar Energía Inclina Cómo Nivelar UNA Cocina Independiente Instrucciones DE InstalaciónInstrucciones Operadoras SurjaCocina Número DE Cazuelas Posición EN LA Bandeja Alimento Posición DE LA BandejaPara hacer funcionar el horno Circulación de aire dentro del hornoPara asar a la temperatura máxima asado regular GratinarNo Sumerja LAS Resistencias EN Agua Cuidados Y LimpiezaAntes DE Llamar AL Servicio Técnico Problema Posible Causa SoluciónElectric Range Cuisinière ÉlectriqueHorno Electrico Read and Save These Instructions Prepare to Install the Range Electrical Connections Electrical Requirements Conductor Power Cord Installation Terminal Block For conduit installations only Operating Position
Related manuals
Manual 32 pages 59.77 Kb

DER2009W specifications

The Danby DER2009W is a sleek and efficient portable air conditioner designed to provide optimal cooling in any living space. With a cooling capacity of 9,000 BTUs, this unit is perfect for cooling smaller rooms up to approximately 350 square feet. Its compact design makes it easy to move from one room to another, ensuring comfort is always within reach.

One of the main features of the DER2009W is its high efficiency. It boasts an Energy Efficiency Ratio (EER) of 12.1, which means it consumes less energy while delivering powerful cooling performance. This can lead to reduced energy bills, making it an environmentally friendly choice for consumers looking to lower their carbon footprint.

The air conditioner comes equipped with multiple cooling and fan speeds, allowing users to customize their comfort. The three fan speeds and three cooling settings ensure that you can fine-tune the airflow and temperature according to your preferences. Additionally, the unit features a programmable thermostat, which allows users to set specific temperature levels for different times of the day, enhancing energy efficiency.

The DER2009W employs modern technologies to enhance the user experience. It includes an easy-to-use digital interface with a remote control, allowing for convenient adjustments from anywhere in the room. The sleep mode feature automatically adjusts the temperature during nighttime hours for increased comfort while minimizing energy consumption. Furthermore, the 24-hour timer provides flexibility, allowing users to set the unit to turn on or off at designated times.

Another significant characteristic of the Danby DER2009W is its low noise operation. With an indoor noise level measuring around 53 dB, it runs quietly in the background, making it suitable for use in bedrooms, offices, or other quiet environments.

Additionally, the unit includes a built-in dehumidifier function, capable of removing excess humidity from the air, which is particularly beneficial during hot and humid summer months.

Overall, the Danby DER2009W combines efficiency, convenience, and advanced features, making it an excellent choice for those in need of a portable air conditioning solution. Its modern design and user-friendly controls ensure a comfortable environment, while its energy-efficient performance provides peace of mind for environmentally conscious consumers.