b. MODELS REQUIRING POWER SUPPLY CORD KIT

RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED.

This appliance may be connected by means of a power supply cord. Only a power supply cord kit rated 120/240 volts, 40 amperes and marked for use with ranges shall be used.

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords must be provided with closed-loop terminals on wire and a strain relief device properly installed.

A time-delay fuse or circuit breaker is recommended.

Local codes may permit the use of a UL-listed, 250 volt, 40 amp range power supply cord (pigtail) This cord contains three No. 10 copper wires and matches a 3-wire receptacle of NEMA Type 10-50R. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance.

The range can be connected directly to the fused disconnected (or circuit breaker box) through flexible armored conduit. Allow 2 to 3 feet of slack in the line so that it can be moved if servicing is ever necessary.

o An UL-listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box)

o Wire sizes and connections must conform to the rating of the range (40 amp)

The wiring diagram is located on the back of the range in a bag.

For power cord installations only:

WARNING: Electrical Shock Hazard

Disconnect power before servicing.

Plug into a grounded outlet.

Use a new 40Amp power supply cord.

Failure to follow these instructions can

 

 

 

result in death, fire or electrical shock.

Assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.

Important: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover.

3-CONDUCTOR POWER CORD INSTALLATION

Use this method only if local codes permit connecting cabinet-ground conductor to neutral wire of power supply cord.

Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will then be accessible.

Remove the knockout ring (1 3/8”) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.

Assemble a U.L.-listed strain relief in the opening.

Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal block.

Use only ring terminals to connect the power supply.

Use a ¼” nut driver and remove the hex washer head nuts from the terminal block.

Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for proper electrical connection. Do not remove the ground strap.

Tighten the strain relief screws.

Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire cover and main back.

Image 37
Contents Mise EN Garde Precaución Please do this NOW WelcomeProper Installation Important Safety InformationBefore First USE Important Safegaurds Important Safety Information cont’dEnergy Saving Tips Safegaurds cont’dSurface Cooking Oven CookingLeveling a Free Standing Range Installation InstructionsElectrical Surface Operating InstructionsCooking RememberOven Food Rack PositionNumber of Pans Position on Rack To Broil at Controlled Temperatures Auto Vari Broil To Broil at Maximum Temperature Regular BroilBroiling Programmed Oven CookingNot Immerse Element in Water Care and CleaningProblem Possible Cause Solution TroubleshootingNuméro de Modèle Numéo de Type Numéro de Serie Date d’achat BienvenueConsignes DE Sécurité Importantes Installation CorrecteAvant LE Premier Usage Mises EN Garde Importantes Consignes DE Sécurité Importantes suiteMises EN Garde LES Suggestions Déconomie DénergieImportantes suite Cuisson au dessus de la cuisinièreMise À Niveau D’UNE Cuisinière Autostable Instructions DinstallationÉlectriques Rappel Consignes D’UTILISATIONQuelle batterie de cuisine utiliser LA Cuisinière Cuisson DansNombre D’ Ustensiles Position SUR LA Grille Grilloir LA Cuisson AUCuisson au four préprogrammée Avant de commencer la cuissonChauffant Dans L’EAU Soins ET EntretienDépannage Probleme Cause Probable Solution800-26 Sírvase Realizar LO Siguiente Ahora BienvenidaAntes DE Utiliza Primero Información Importante DE SeguridadInstalación Apropiada Importante Para LA Seguridad Seguridad cont’d Importante Para LAPara Ahorrar Energía Inclina Cómo Nivelar UNA Cocina Independiente Instrucciones DE InstalaciónSurja Instrucciones OperadorasCocina Para hacer funcionar el horno Alimento Posición DE LA BandejaCirculación de aire dentro del horno Número DE Cazuelas Posición EN LA BandejaPara asar a la temperatura máxima asado regular GratinarNo Sumerja LAS Resistencias EN Agua Cuidados Y LimpiezaAntes DE Llamar AL Servicio Técnico Problema Posible Causa SoluciónCuisinière Électrique Electric RangeHorno Electrico Read and Save These Instructions Prepare to Install the Range Electrical Connections Electrical Requirements Conductor Power Cord Installation Terminal Block For conduit installations only Operating Position
Related manuals
Manual 32 pages 59.77 Kb

DER2009W specifications

The Danby DER2009W is a sleek and efficient portable air conditioner designed to provide optimal cooling in any living space. With a cooling capacity of 9,000 BTUs, this unit is perfect for cooling smaller rooms up to approximately 350 square feet. Its compact design makes it easy to move from one room to another, ensuring comfort is always within reach.

One of the main features of the DER2009W is its high efficiency. It boasts an Energy Efficiency Ratio (EER) of 12.1, which means it consumes less energy while delivering powerful cooling performance. This can lead to reduced energy bills, making it an environmentally friendly choice for consumers looking to lower their carbon footprint.

The air conditioner comes equipped with multiple cooling and fan speeds, allowing users to customize their comfort. The three fan speeds and three cooling settings ensure that you can fine-tune the airflow and temperature according to your preferences. Additionally, the unit features a programmable thermostat, which allows users to set specific temperature levels for different times of the day, enhancing energy efficiency.

The DER2009W employs modern technologies to enhance the user experience. It includes an easy-to-use digital interface with a remote control, allowing for convenient adjustments from anywhere in the room. The sleep mode feature automatically adjusts the temperature during nighttime hours for increased comfort while minimizing energy consumption. Furthermore, the 24-hour timer provides flexibility, allowing users to set the unit to turn on or off at designated times.

Another significant characteristic of the Danby DER2009W is its low noise operation. With an indoor noise level measuring around 53 dB, it runs quietly in the background, making it suitable for use in bedrooms, offices, or other quiet environments.

Additionally, the unit includes a built-in dehumidifier function, capable of removing excess humidity from the air, which is particularly beneficial during hot and humid summer months.

Overall, the Danby DER2009W combines efficiency, convenience, and advanced features, making it an excellent choice for those in need of a portable air conditioning solution. Its modern design and user-friendly controls ensure a comfortable environment, while its energy-efficient performance provides peace of mind for environmentally conscious consumers.