G |
Fig. 2.14 |
ADJUSTMENT OF THE OVEN BURNER MINIMUM
This needs to be done only for the oven burner (the broil is a fixed capacity) by acting on the thermostat in the following way:
–Turn on the burner by setting the thermostat knob on position .
–Remove the knob and unscrew the
–
to position (minimum) to operate the thermostat
–After having removed the knob again and being very careful not to turn the tap rod, slowly screw the
N.B. For LP/PROPANE gas the
After regulation repeat the operations indicated in paragraph “2. Pressure regulator” at page 9.
If the range has been disconnected and then connected again to the gas supply line repeat the operations indicated in paragraph “5. Leak Testing” at page 12.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out affix inside the drawer, near the data plate, the conversion label supplied and also affix a conversion label at page 3 of this instruction manual.
16