DeLonghi DEFSGG 24 SS Proximity to Side Cabinets, GAS and Electric Connection

Page 6

4" 7/16

(113 mm)

MIN 35" 7/16 (900 mm)

MAX 36" 7/32 (920 mm)

 

 

24"

 

(611.

5/64

6

 

mm)

Fig. 1.1

23"

7/8

 

mm)

.5

 

(606

 

 

installation

PROXIMITY TO SIDE CABINETS

1.This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets.

Range dimensions:

width: 23” 7/8 (606.5 mm)

depth: 24” 5/64 (611.6 mm)

height (without backguard): MIN 35” 7/16 (900 mm) - MAX 36” 7/32 (920 mm)

backguard (height): 4” 7/16 (113 mm)

Gas line opening:

Wall - 5” 57/64 (150 mm) from the floor; 11” 15/16 (303 mm) from the rear left side of the range.

Grounded outlet: the electric cord with 3-prong ground plug has a length of 72” (1830 mm). Grounded outlet should be located 5” 57/64 (150 mm) from the floor and 11” 15/16 (303 mm) from the rear right side of the range.

2.The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm) high.

There must be a minimum of 3” (76 mm) side clearance from the range to such combustible surfaces TO THE LEFT above the 36” (914 mm) high countertop; or there must be a minimum of 11” 13/16 (300 mm) side clearance from the range to such combustible surfaces TO THE RIGHT above the 36” (914 mm) high countertop.

IMPORTANT: One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.

3.The maximum upper cabinet depth recommended is 13” (330 mm). Wall cabinet above the range must be a minimum of 30” (762 mm) above the countertop for a width of minimum 24” (609.6 mm): it has to be centred with the range. Side wall cab- inets above the range must be a minimum of 18” (457 mm) above the countertop.

GAS AND ELECTRIC CONNECTION

Dotted line showing the position of the range when installed

Area for GAS connection

11" 15/16

11"

15/16

(303

mm)

(303

mm)

 

 

 

 

 

 

 

Area for ELECTRICAL connection

5" 57/64 (150 mm)

Fig. 1.2

6

Image 6
Contents GAS Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Electrical Requirement Replacement PartsElectrical Grounding Instructions Air Supply and VentilationProximity to Side Cabinets GAS and Electric ConnectionIt is mandatory to install the backguard Assembling the BackguardANTI-TIP Stability Device Installation Instructions Levelling the RangeManual Shut-off Valve fig Explosion HazardPressure Regulator Pressure Regulator Installation Step GAS Connection Specification ConnectorExtension Leak Testing Flexible ConnectionsRigid Pipe Connections Setting the Pressure Regulator .6b Conversion to LP/PROPANE GASTo set the pressure regulator Operations to be Performed When Substituting the Injectors Setting the Burner MinimumInjectors Table Oven Burner Broil BurnerAdjustment of the Oven Burner Minimum Electrical connection Recommended ground methodWiring Diagram TL3Page Cod ß3