GE PVWS930, PVWT936 Ducting Options and Examples, Model PVWG936, Model PVIG940, Venting Methods

Page 11

Installation Instructions

PARTS PROVIDED - Continued

MODEL PVWG936

Hood canopy with internal blower, grease filters and lights already installed

Glass vapour catcher

Duct covers

Duct Cover support bracket

Transition (may be already installed)

Hardware Packet:

Note: the hardware packet contains several ￿ttings material. For model PVWG936, consider what is listed below ONLY:

Allen Wrench

Lower support bracket x 2 (to attach the hood canopy)

Rubber tape (for glass vapour catcher)

Bushes x 4 (for glass vapour catcher)

6 x 20 screws x 4 (for glass vapour catcher)

Template

Use, Care and Installation Guide

10 x 60 drywall anchors x 2 (To attach duct cover support bracket)

•6 x 80 screws x 6 +washers x 6 (2 To attach duct cover support bracket + 4 to attach the hood canopy)

•3,5 x 9,5 screws x 14 (2 to attach the transition + 4 to attach the duct cover + 8 to attach the lower support brackets)

MODEL PVIG940

Hood canopy with internal blower, grease filter and lights already installed

Glass vapour catcher

Duct covers

Chimney structure

Transition (may be already installed)

Use, Care and Installation Guide

Hardware Packet:

Note: the hardware packet contains several ￿ttings material. For model PVIG940, consider what is listed below ONLY:

Allen Wrench

Rubber tape (for glass vapour catcher)

Bushes x 4 (for glass vapour catcher)

6 x 20 screws x 4 (for glass vapour catcher)

Template

•6 x 80 screws x 4 + washers x 4(To attach the chimney

structure to the ceiling)

 

 

•3,5 x 9,5 screws x 16 (8 to assemble the structure + 4 to

attach the duct covers + 2 to attach the transition + 2 to

attach the junction cover (may be

already

intsalled))

• 8 x 16 screws x 4 (to attach the

canopy

to the structure).

1 Ft = 0.3 m 1” = 2.5 cm

DUCTING OPTIONS AND EXAMPLES

Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.

Venting Methods

The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version) .

Models PVWS930/936 and PVWT936: Minimum Duct

Size (Ducting/Ductless version): 5" Round Pipe.

Models PVWG936 and PVIG940: Minimum Duct Size

(Ducting/Ductless version): 6" Round Pipe.

Models PVWS930/936, PVWT936

Model PVIG940

 

and PVWG936

 

 

 

 

 

Roo

f Pitch w/Flashing and

Cap

Roof Pitch

w/Flashing and Cap

 

 

 

 

 

 

 

 

 

 

 

PipePipe

Pipe

Sidewall Cap with Gravity Damper

 

Ducted Version

 

Ducted Version

 

Preparation

 

 

 

 

 

 

Do not

cut a joist or stud unless

absolutely necessary. If

a joist or stud must be cut, then a supporting frame

must be

constructed.

 

 

 

Fittings material is provided to secure the hood to most types of walls/ceilings.

However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.

Min. installation height from the range top to the bottom of the

.hood is 30” it a gas range is used or 24” to 30” if an electric range is used.

These Hoods are not recommended to be used over indoor grills.

Check your ceiling height and the hood height maximum before you select your hood.

1 1

Image 11
Contents 350A4502P595 03-07 ATS Range HoodsImportant Safety Information Safety Precautions Filters Using the hood controlsControl Device Reset Hood OperationStainless Steel Surfaces Care and cleaning of the vent hoodTo clean the filter/s To clean the hood surfaceCare and cleaning of the vent hood Range Hood Product Dimensions Installation InstructionsFlexible ducting Duct FittingsModels PVWS930, PVWS936 and PVWT936 Optional AccessoriesTools and Materials Required Parts ProvidedVenting Methods Ducting Options and ExamplesModel PVWG936 Model PVIG940For Models PVWS930, PVWS936, PVWT936 and PVWG936 only Wall InstallationWall Installation 5 x Duct Cover For Model PVIG940 only Ceiling InstallationCeiling Installation Page Before you call for service… Ownership Registration For Canadian Customers Pour les consommateurs canadiens What Mabe Will Not Cover Range Hood WarrantyMabe Will Replace Extended Warranties Schedule ServiceParts and Accessories Consumer Support GE Appliances Website