GE PVIG940 Wall Installation, For Models PVWS930, PVWS936, PVWT936 and PVWG936 only

Page 12

Installation Instructions

WALL INSTALLATION

FOR MODELS PVWS930, PVWS936, PVWT936 AND PVWG936 ONLY

(For model PVIG940 installation, please refer to the paragraph "CEILING INSTALLATION" on the next pages).

1.Choose the assembly height which is most convenient for the user and mark the wall behind the hob.

2.Mark the centre line of the hood and trace the vertical line from the bottom of the hood to the ceiling.

3.Fasten the template using adhesive tape, making sure the centre line corresponds with the bottom of the hood.

4.Mark the centre of the fixing points (6 fixing points for models PVWS930/936 and PVWT936; 4 fixing points for model PVWG936) through the template on the wall and then remove the template.

5.Trace a horizontal line on the wall 1” above the highest fixing point and 1” below the lowest fixing point.

6.Find studs behind drywall by tapping wall or using a stud finder. Mark the center of the studs with a vertical line to the right and left of the marked fastener location.

7.Note: All fastener location must span the studs otherwise proceed as follows:

Cutout drywall along marked lines.

Install wood blocking between studs and make sure it is flush with existing stud front. Make sure all mounting screws will anchor to added studs.

Replace drywall and refinish.

8.Mark the centre line again and the bottom of the hood in same position as before and fasten the template to the wall using adhesive tape as indicate above at point 3.

Models PVWS930/936 and PVWT936

A.Centerline

B.Mounting Hook Location

C.Fastener Locations

D.Mounting Height Reference

E.Template

Model PVWG936

A.Centerline

B.Mounting Hook Location

C.Fastener Locations

D.Mounting Height Reference

E.Template

9.Models PVWS930/936 and PVWT936:

Attach the 2 hooks with leveling screws (provided in the assembly kit) to the points marked on the template with 2 screws and then remove the template.

Model PVWG936:

Screw 2 screws on lower fixing point but do not tighten them completely (leave a space of ½") they will serve to hang the hood canopy.

Models PVWS930/936 and

 

Model PVWG936

PVWT936

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ø 6 x 80

Ø 6 x 80

A.Centerline

B.Mounting Hooks (screws)

C.Fastener Locations

10.Install the bracket flush with the ceiling using the drywall anchors provided with the appliance.

Models PVWS930/936 and

 

Model PVWG936

PVWT936

 

 

 

Ø 10 x 60

Ø 6 x 80

 

Ø 10 x 60

 

 

 

 

Ø 6 x 80

 

 

 

 

 

11.Determine and make all necessary cuts in the wall for the vent system. Install the vent system before the canopy hood. See „Venting methods“ paragraph.

12.Determine the required height for the conduit and cut a 1¼" hole at this location. Run wires through hole according to the National Electrical Code or CSA Standards and local codes and ordinances. Note: If a In-line blower installation is required/ needed, then provide an additional hole/conduit.

There must be enough power supply cable from the fused disconnect (Or circuit breaker) box to make the connection in the hood’s Junction box/es.

Use caulking to seal all openings.

Do Not turn on power until installation is completed.

1Ft = 0.3 m 1” = 2.5 cm

1 2

Image 12
Contents Range Hoods 350A4502P595 03-07 ATSImportant Safety Information Safety Precautions Using the hood controls Control Device ResetHood Operation FiltersCare and cleaning of the vent hood To clean the filter/sTo clean the hood surface Stainless Steel SurfacesCare and cleaning of the vent hood Range Hood Installation Instructions Product DimensionsDuct Fittings Flexible ductingOptional Accessories Tools and Materials RequiredParts Provided Models PVWS930, PVWS936 and PVWT936Ducting Options and Examples Model PVWG936Model PVIG940 Venting MethodsWall Installation For Models PVWS930, PVWS936, PVWT936 and PVWG936 onlyWall Installation 5 x Duct Cover Ceiling Installation For Model PVIG940 onlyCeiling Installation Page Before you call for service… Ownership Registration For Canadian Customers Pour les consommateurs canadiens Range Hood Warranty Mabe Will ReplaceWhat Mabe Will Not Cover Schedule Service Parts and AccessoriesConsumer Support GE Appliances Website Extended Warranties
Related manuals
Manual 22 pages 2.66 Kb

PVWS936, PVIG940, PVWG936, PVWS930, PVWT936 specifications

The GE PVWS936, PVWT936, PVWS930, PVWG936, and PVIG940 are part of General Electric's advanced lineup of water and wastewater management solutions. These models reflect GE's commitment to delivering innovative technology, energy efficiency, and operational reliability in the realm of water treatment.

One of the standout features of the GE PVWS936 and PVWT936 is their robust filtration capabilities, designed to handle a variety of water quality issues. These models incorporate advanced membrane technology which enhances the efficiency of contaminant removal while minimizing energy consumption. This leads to significant cost savings in chemical usage and maintenance, a valuable proposition for municipalities and industrial applications alike.

The PVWS930 model emphasizes versatility and ease of operation. It is equipped with user-friendly interfaces and remote monitoring capabilities, allowing operators to track performance metrics in real-time. This feature not only streamlines operations but also aids in proactive maintenance, reducing downtime and extending the life of the equipment.

Another notable characteristic is observed in the PVWG936, which boasts a compact design without compromising on performance. It is engineered to maximize space utilization in treatment facilities, making it ideal for sites where footprint is a concern. This model is particularly well-suited for urban settings where space limitations are increasingly becoming an operational hurdle.

The GE PVIG940 focuses on integrated growth with an emphasis on sustainability. This model goes beyond just treating water; it's designed to promote environmental stewardship by incorporating energy-efficient components and reducing carbon footprint. Its ability to integrate with renewable energy sources underscores GE's commitment to sustainable development in water management.

All these models share common technological advancements such as enhanced automation, data analytics, and IoT integration. The data analytics capabilities allow operators to make informed decisions based on real-time data, leading to improved operational efficiencies. Furthermore, the IoT integration enables predictive maintenance, ensuring that systems are functioning optimally and reducing the likelihood of unexpected failures.

Overall, the GE PVWS936, PVWT936, PVWS930, PVWG936, and PVIG940 are engineered to meet the demands of modern water treatment processes. Their advanced features, emphasis on energy efficiency, and commitment to sustainability make them exceptional choices for both municipal and industrial applications. As water scarcity and quality issues continue to challenge communities worldwide, these models present effective solutions that align with the best practices in environmental management.