Dimplex Purifire Electric Stove manual Manual Selection Switch, Maintenance

Page 7

MANUAL SELECTION SWITCH

Operates the electric fireplace in the same manner as the remote control transmitter. Pressing the switch up (“ I ” position) has the same effect as the ON button on the remote control and pressing the switch down (“ II ” position) has the same effect as the OFF button of the remote control. Pressing the switch up once activates Level 1, twice activates Level 2, three times activates Level 3. Pressing the switch down turns the electric fireplace OFF.

Level 1: The flame effect is turned on and the first red indicator light flashes momentarily.

Level 2: The flame effect remains on, the heater is activated to the low heat setting, and the first and second red indicator lights flash momentarily.

Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicators flash momentarily.

MAINTENANCE

WARNING

Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.

LIGHT BULB REPLACEMENT

Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin.

Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are two bulbs under the log set which generate the flames and embers.

TOOL REQUIREMENTS

Slot screw driver

HELPFUL HINTS

It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs.

UPPER LIGHT BULB REQUIREMENTS Quantity of 1 –15 watt candelabra E12 small base 120 volt.

DO NOT EXCEED 15 WATTS

UPPER BULB REPLACEMENT

1.Remove the 2 screws at the upper corners of the back panel. Lift the back end of the top to clear the brackets and pull back. Lift top carefully, and place to the side of the stove. Caution should be taken as the top mounting brackets may scratch the finish.

2.Remove the burnt bulb by pushing in and turning counter-clockwise.

3.Replace the upper light bulb.

4.Reassemble in the reverse order as above.

LOWER LIGHT BULB REQUIREMENTS Quantity of 3 – 35 watt Halogen Quartz lamps, 120 volt, G9 base.

DO NOT EXCEED 35 WATTS PER BULB

Upper Light Bulb

Lower Light Bulbs

5

Image 7
Contents Serial Number Model Number CAT Number Quick Reference Guide for the Dimplex Electric Fireplace ContentsPlease Retain this USER’S Guide for Future Reference Important InstructionsImportant Instructions Resetting the Temperature Cutoff Switch Stove InstallationOperation Remote Control Initialization Remote Control UsageMaintenance Manual Selection SwitchPurifire Filter Lower Bulb ReplacementStove Surface Cleaning Glass CleaningProducts to which this limited warranty applies TWO Year Limited WarrantyHow State and Provincial law apply Dimplex