LOWER BULB REPLACEMENT
1.Gently place stove on its back on a flat surface.
2.Remove thermostat knob.
3.Remove the heater cover retaining screws located on the bottom of the stove and lower heater and light assembly out onto the floor.
4.Remove the burnt out bulb(s) by pulling straight out of socket. If bulbs are difficult to remove from socket move the bulb from side to side while pulling being careful not to damage the light socket.
5.Replace the lower light bulbs.
6.Reassemble in the reverse order as above.
Screws
Screws
PURIFIRE™ FILTER
The Purifire™ filter supplied in your stove is reusable and washable. The filter should be cleaned or replaced on average once a year. To clean the filter gently tap filter on a hard surface to dislodge any loose dirt or debris, and then clean with water. No soap or cleaning products are recommended. The filter size is 20” X 10” X 1” rated at MERV 10. If using an after market filter follow the manufacturers recommended replacement instructions.
To replace filter:
1.Remove the 2 screws at the upper corners of the back panel.
2.Lift the back end of the top to clear the brackets and pull back.
3.Lift top carefully, and place to the side of the stove. Caution should be taken as the top mounting brackets may scratch the finish.
4.Slide filter out of air filter bracket.
5.Reassemble in reverse order as above.
Filter
6