3-Wire Power Cord Installation
• Remove the Terminal Block Access Plate on the back |
| |
of range by removing the 2 fixing screws. | Screws | |
• Assemble the strain relief in the hole on bracket. | ||
| ||
• Insert the power cord through the strain relief and |
| |
tighten. |
| |
• Allow enough slack to easily attach the cord terminals |
| |
to the terminal block. |
| |
• Remove the 3 wire terminal nuts and washers from | Terminal Block | |
the terminal block. | ||
Access Plate |
•Plug the terminal holes of power cord. The neutral or
ground wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The power leads must be connected to the outside terminals.
• Plug washers and tighten nuts securely.
• Assemble the Terminal Block Access Plate.
•Remove the Terminal Block Access Plate on the back
of range by removing the 2 fixing screws. | Cut Ground Strap | Grounding Screw |
• Assemble the strain relief in the hole on bracket. | Terminal Block |
|
• Insert the power cord through the strain relief and | Neutral Wire |
|
|
| |
tighten. | Grounding Wire |
|
• Allow enough slack to easily attach the cord terminals | Power Wires |
|
to the terminal block. | Power Cord |
|
• Remove the 3 wire terminal nuts and washers from |
| |
Bracket |
| |
the terminal block. |
| |
|
|
•Remove the ground strap from the frame of range and terminal by removing its screw and cutting is as shown.
•Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The ground wire of the power supply cord must be attached to the frame of range by using the green colored grounding screw. The power leads must be connected to the outside terminals.
•Plug washers and tighten nuts securely.
•Assemble the Terminal Block Access Plate.
←LEVELING THE RANGE
The range must be level to obtain proper operating. The four screws type leveling legs located on the corners at the bottom of range should be adjusted by turning them clockwise to make the range higher or
17