Bertazzoni X244GGVX dimensions Replacement Parts, Conversion to different types of gas

Page 11

REPLACEMENT PARTS

Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available from factory authorized parts distributors.

Conversion to different types of gas

Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig.

Adaptation of the pressure regulator for use with different type of gas

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre-arranged from the factory to operate with one of these gas/pressure as indicated in the labels affixed on the appliance, package and Instruction booklet.

To convert the regulator for use with other types of gas follow these instructions:

1)Unscrew by hand the upper metal stopper of the regulator.

2)Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw it again in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with relative indicating arrows on the white piece).

3)Screw again by hand the metal stopper in the original position on the regulator.

Following these exact instructions the gas regulator is converted for use with the other gas/pressure.

It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage

-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:

To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE shown below.

11

Image 11
Contents Bertazzoni What to do if YOU Smell GAS Installation instructions Installation Manual Height adjustable legs Backguard Installation InstructionWorktop Frontguard Installation Instructions Installation SIDE-BY-SIDE to Kitchen Cabinet Electrical Connection Cooker Hood InstallationManual Shut-off Valve GAS ConnectionFlexible Connections 5 cm 37,6 cm 820,3 cmConversion to different types of gas Replacement PartsModels X244GGVX Regulation of Burners Service & Maintenance InstructionsDisconnect power before servicing unit Descriptions Control Panel Description Using BurnersTips for using burners correctly Correct usage of pans Using the GAS OvenTemp F/ C Height Minutes Meat Electric ignitionUsing the GAS Broiler After Sale Service Cleaning the ApplianceSpare Parts List Warmer Drower Upperside Protection Panel Page Page Page Page Page