Bertazzoni X244GGVX dimensions Regulation of Burners, Service & Maintenance Instructions

Page 13

REGULATION OF BURNERS

Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:

1)Light the burner and set the knob to the MINIMUM position (small flame).

2)Remove the knob of the valve that is press fit on the rod of that valve.

3)The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum

4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

Oven burner adjustment: follow the instructions below to adjust the minimum:

1)Light the burner setting the knob to the MAXIMUM position.

2)Close the oven door and operate the oven for at least 10 minutes.

3)Set the knob to the MINIMUM position (corresponding to 250°F/120°C) and then remove it.

4)With a slotted screwdriver turn the choking screw (by-pass screw at the left side of the thermostat bar) and, while observing the flame at the same time through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the MINIMUM to the MAXIMUM position.

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with liquid gas the screw must be locked at the end in a clockwise direction. The broiler burner always operates at maximum and therefore no minimum adjustment is required.

SERVICE & MAINTENANCE INSTRUCTIONS

Service and maintenance only to be carried out by an authorised person

To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop. Note: if the valves must be replaced, first disassemble the ignitions switches wires.

It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the body and the gas train.

WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of the appliance, make the leak test using water with soap on the gas connections in order to verify the correct installation. Do not use fire for gas leak testing.

To replace the oven bulb, just unscrew the protection cap that projects out inside the oven. (Fig.19) WARNING:

Disconnect power before servicing unit.

In order to remove the oven door make sure to block the ihinges with a screw driver.

Call an autorised service person for this operation that can be dangerous

13

Image 13
Contents Bertazzoni What to do if YOU Smell GAS Installation instructions Installation Manual Height adjustable legs Backguard Installation InstructionWorktop Frontguard Installation Instructions Installation SIDE-BY-SIDE to Kitchen Cabinet Electrical Connection Cooker Hood InstallationManual Shut-off Valve GAS ConnectionFlexible Connections 5 cm 37,6 cm 820,3 cmConversion to different types of gas Replacement PartsModels X244GGVX Disconnect power before servicing unit Service & Maintenance InstructionsRegulation of Burners Descriptions Tips for using burners correctly Using BurnersControl Panel Description Correct usage of pans Using the GAS OvenTemp F/ C Height Minutes Meat Electric ignitionUsing the GAS Broiler After Sale Service Cleaning the ApplianceSpare Parts List Warmer Drower Upperside Protection Panel Page Page Page Page Page