Fig. 2.3

Bracket

Fixing Screws

Bracket

Strain Relief

Fig. 2.4

Opening For

Electrical

Connection

Fixing Screws

Power Cord

Bracket

Fig. 2.5

Terminal Block

 

Ground strap

Neutral Wire

 

Power Wires

 

Power Cord

 

Strain Relief Bracket

 

Screws

Power Cord

 

Power Cord

Bracket

 

Fig. 2.6

Terminal Block

Cut Ground Strap

Grounding Wire

Neutral Wire

 

Power Wires

 

 

Power Cord

 

 

Strain Relief Bracket

Grounding Screw

 

 

 

Screws

Power Cord

 

 

10

Power Cord

Bracket

 

 

 

3-Wire Power Cord Installation

(See Figures 2.1, 2.3, 2.4 and 2.5)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (fig. 2.3).

3.Mount the Power Cord Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 2.4).

4.Insert the Power Cord through the Power Cord Bracket; then tighten the Power Cord by using the Power Cord Strain Relief Bracket (fixed by 2 screws). Allow enough slack to easily attach the cord terminals to the Terminal Block.

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Plug the terminal holes of Power Cord. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.

7.Plug washers and tighten nuts securely. Do not remove Ground strap.

8.Assemble the Terminal Block Access Plate.

4-Wire Power Cord Installation

(See Figures 2.1, 2.3, 2.4 and 2.6)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (fig. 2.3).

3.Mount the Power Cord Bracket (supplied with the range in a separate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in figure 2.4).

4.Insert the Power Cord through the Power Cord Bracket; then tighten the Power Cord by using the Power Cord Strain Relief Bracket. Allow enough slack to easily attach the cord terminals to the Terminal Block (fig. 2.6).

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Remove the Ground Strap from the frame of range and terminal by removing its screw and cutting it as shown in figure2.6.

7.Plug the terminal holes of Power Cord. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.

8.Plug washers and tighten nuts securely.

9.Assemble the Terminal Block Access Plate.

Image 10
Contents Electric Range ALL Ranges can TIP Installation Instructions Replacement Parts Electrical Grounding InstructionsProximity to Side Cabinets Electric ConnectionIt is mandatory to install the backguard ASSEMBLING THE BACKGUARDANTI-TIP Stability Device Installation Instructions Levelling the RangeElectrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit Wire Flat Power Cord Installation Wire Power Cord Installation Wire Conduit Installation Wiring Diagram Double ZonePage Page Page Cod ß2