Harman Stove Company MARK III manual Introduction, Safety Notice

Page 3

Introduction

Thank you for purchasing a Harman Magnafire coal stove. The Magnafire series has been designed and built to last. Whether you’re heating a room or heating your whole house, you’ve made the right choice. Please read this entire instruction manual before attempting to install or operate your new stove. If you have further questions regarding your new stove, contact your Harman dealer. Follow these instructions and you will have many years of warmth and comfort enjoying your new coal stove.

If you are a first-time coal burner, keep in mind that you will not have instant success with maintaining a fire. No one does. Following these instructions should help you with the basic principals.

Please copy your serial number, from the label on the back of your stove, to the box below.

THis appliance is also approved for installation into a shop.

LIS TED SOLID FUEL (COAL) FIREPLACE STOVE OR ROOM HEATER

POÊLE (DE CHARBON) DANS UN FOYER OU APPAREIL DE CHAUFFAGE

OMNI-Test Laboratories, Inc.

MODEL/Modèle: MARK I

Serial No.

 

Tested to/Testé à:

MARK II

No de série: 008

BARCODE LABEL

Report #/Rapport #135-S-07-4

 

 

 

UL 737, UL 1482, June 1985

MARK III

 

 

Meets requirements of ULC S627/

 

 

Selon les exigences de ULC S627

CONTACT YOUR LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA/

Certifi ed for U.S.A. and Canada/Certifi é

pour les États-Unis et le Canada

CONTACTEZ LE BUREAU DE LA CONSTRUCTION OU LE BUREAU DES INCENDIES AU DES RESTRICTIONS ET DE L’INSPECTION D’INSTALLATION DANS VOTRE VOISINAGE

PREVENT HOUSE FIRES:

Install and use only in accordance with manufacturer’s installation and operation instructions and local building codes. In absence of any local codes, installation must meet minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. Inspect and clean chimney system frequently in accordance with manufacturer’s instructions.

FOR USE WITH COAL ONLY.

Don’t connect this stove to a chimney serving another appliance.

Flue connector pipe must be 6” diameter, minimum 24 MSG black or 26 MSG blue steel. Chimney must be factory built 103HT or masonry.

NOTE: Replace glass only with 5mm ceramic glass available from your dealer.

Inspect and clean chimney frequently. Under certain condictions of use, creosote buildup may occur rapidly.

DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING.

PRÉVENTION DES FAUX DE MAISON:

Installez et utilisez en accord avec les instructions d’installation et d’opération du fabricant et des codes locaux. S’il n’y a pas de codes lacaux. l’installation doit suivre kes exigences minimum de NFPA 211 aux États-Unis. Référez vous aux instructions du fabricant et des codes locaux pour les précautions pour passer une cheminée à travers un mur ou unplafond combustibles. Inspectez et nettoyez le systèm de chiminée fréquemment en accord avec les instructions du fabricant.

UTILISER SEULEMENT DU CHARBON

Ne pas connecter cet appareil à un tuyau de cheminée servant un autre appareil.

Le tuyau connector doit être de 6” de diamètre, d’acier noir de minimum de 24 MSG ou d’acier bleu de 26 MSG.

La cheminée doit être bâtit à l’usine de 103 HT ou faite en briques.

Note: Remplacez la vitre seulement avec une vitre céramique de 5mm disponible chez votre fournisseur.

Inspectez et nettoyez la cheminée fréquemment. Sous certaines conditions. il se peut que la créosote s’accumule rapidement.

NE PAS SURCHAUFFER. SI L’APPAREIL DE CHAUFFAGE OU LE TUYAU DE CHEMINÉE ROUGISSENT. VOUS SURCHAUFFEZ.

Listed by: OMNI-Test Laboratories, INC Report # 135-S-07-4

CLEARANCE TO COMBUSTIBLE SURFACE

 

 

BACKWALL

 

ESPACES LIBRES AUX COMBUSTIBLES

 

Floor protection must be a 3/8” min. thickness,

 

A - Unit to Sidewall

33”

SIDEWALL

C

D

B

A - Du mur de côté à l’appareil

33”

 

B - Unit to Backwall

24”

 

STOVE

 

B - Du mur arrière àl’appareil

24”

non-combustible material or equivalent, extending

 

C - Chimney Connector to Side Wall

42”

 

A

 

 

C - Du tuyau de cheminée au mur de côté

42”

beneath heater and to front/sides/rear as indicated

 

 

 

 

 

on the diagram

 

D - Chimney Connector to Back Wall

18”

 

 

 

 

D - Du tuyau de cheminée au mur arrière

18”

 

 

 

 

 

 

 

E - Floor Protector, Side and Rear

8”

 

 

H

 

E - Du plancher protecteur, Côté arrière

8”

Leprotecteur de plancher doit être de 3/8”

 

F - Floor Protector, Front

16”

 

 

 

 

F - du plancher protecteur, Devant

16”

 

 

 

D

 

d’épaisseur minimum, fait de matière non

 

H - Pipe conector to Ceiling

18”*

 

 

 

 

H - Du tuyau connecteur au plafond

18”*

 

 

 

B

 

combustible ou équivalent, s’étendant en dessous,

 

*Not Tested - NFPA Guildlines

 

 

 

 

 

*Pas testé - indications NFPA

 

en avant, en arrière et sur les côtés de l’appareil de

 

 

 

 

 

 

 

chauffage comme indiqué sur le diagramme.

 

ELECTRICAL RATING: 115VAC, 60 HZ, 1.1 AMPS

 

 

 

 

 

 

PUISSANCE ÉLECTRIQUE: 115VAC, 60 HZ, 1.1 AMPS

 

DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit.

DANGER: Il y a risque de choque électrique. Déconnectez le fi l électrique avant le service

 

Do not route power cord under or in front of appliance.

 

 

 

 

 

Éloignez le fi l électrique de l’appareil. Ne placez pas le fi l électrique sous ou à l’avant de l’appareil.

CAUTION: RISK OF EXCESSIVE TEMPERATURE AND DAMAGE TO UNIT.

ATTENTION: IL Y A RISQUE DE TEMPÉRATURES EXCESSIVE ET DE DOMMAGE À

PROPER OPERATION REQUIRES THE USE OF ONLY PEA, NUT & COAL STOVE SIZE

L’APPAREIL. UN BON FONCTIONNEMENT EXIGE L’USAGE D’ANTHRACITE DE CHARBON DE

ANTHRACITE COAL

 

 

 

 

 

 

GROSSEUR D’UN POIS, D’UNE NOIX OU D’UN CHARBON.

 

CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH.

 

ATTENTION: CHAUD-NE PAS TOUCHER. TENIR LES

KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY

 

ENFANTS ET LES VENTEMENTS A L’ECART. RISQUE DE

CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.

 

BRULURE. VOIR INSTRUCTIONS SUR LA PLAQUE. LAISSER

KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS

 

UNE DISTANCE SUFFISANTE ENTRE L’APPAREIL ET LES

A CONSIDERABLE DISTANCE AWAY FROM THIS APPLIANCE.

 

MEUBLESOU AUTRES OBJECT A RISQUE.

 

Exempt From EPA Certification under 40 CFR 60.531

 

Manufactured by/Fabriqué par: Harman Home Heating

 

Date of Manufacture / Date de fabrication

 

 

352 Mountain House Road

 

2012 2013 2014 JAN FEB MAR APR

MAY

JUN JUL

 

AUG SEP OCT NOV

DEC

 

 

 

 

 

 

 

 

 

P.N. 3-90-90732

Halifax, Pa 17032

Rev B

 

 

 

 

 

 

 

 

Safety Notice:

Stove is hot while in operation. Keep combustibles such as furniture, fuel, and draperies at least 36 inches away from the appliance.

Do not leave small children unattended while in the room with this heater.

Always wear gloves when attending to the stove.

This stove is not an incinerator. Do not burn garbage, painted or treated wood, or flammable liquids like gasoline kerosene, or engine oil.

3

Magnafire Series Coal Stoves

3-90-70746R8_11/12

Image 3
Contents Magnafire Series Coal Stoves Mark I, II, Installation and Operating Manual90-70746R811/12 Introduction Safety NoticeVenting IndexCuring Paint InstallationUnpacking and Inspection of Parts BurnsAssembly Types of Chimneys Common chimney problemsVenting Venting & ChimneysVenting & Grates GratesGrate System and Controls Operating Instructions OperationPeriodic and Everyday Maintenance MaintenanceMaintenance SafetyPlumbing Diagrams Optional Water CoilOptional Hot Water Coil Circulating Pump Method Thermo- Siphon MethodWarranty Information Warranty CoverageWarranty Period Limitations of Liability Warranty ConditionsWarranty Exclusions This warranty is void ifAt Depot Service PartsService Parts StockedService Parts Stocked At Depot MarkStocked Stocked At Depot Stocked Service & Maintenance Log Service & Maintenance Log 90-70746R811/12 Signature of Boxer
Related manuals
Manual 24 pages 8.94 Kb

MARK II, MARK I, MARK III specifications

Harman Stove Company has established itself as a leader in the production of high-quality wood and pellet stoves. The MARK III, MARK I, and MARK II series represent some of the finest offerings from this esteemed company, showcasing impressive features, innovative technologies, and unique characteristics that cater to a variety of heating needs.

The Harman MARK III is renowned for its robust construction, offering a substantial heat output that can effectively warm larger spaces. One of its standout features is the patented "Smart Heat" technology, which ensures optimal fuel efficiency and consistent heat distribution. The MARK III incorporates a large combustion chamber, capable of accommodating various types of pellets or wood, which enhances its versatility. Additionally, the unit's automatic ignition system simplifies operation, allowing users to easily start a fire with the push of a button. The intense heat produced is further complemented by a sleek design that fits seamlessly into any decor.

The Harman MARK I is designed for those seeking a compact but powerful heating solution. Despite its smaller size, this stove is engineered for maximum efficiency with an efficient burn rate that translates to lower emissions and reduced environmental impact. It features a ceramic glass door that provides a pleasing view of the fire while retaining heat. The MARK I also includes Harman's advanced feed system that ensures steady fuel delivery, optimizing performance and reducing the need for frequent refueling. This model is perfect for small homes or cabins, where space is at a premium but warmth is essential.

The MARK II combines the best of both worlds, offering a balance between size and output. This model incorporates advanced airflow technologies that enhance combustion efficiency and minimize soot buildup. Its flexible installation options make it suitable for a variety of spaces, and its user-friendly digital control panel allows for effortless adjustments to temperature settings. Like its counterparts, the MARK II ensures a clean burn, contributing to improved air quality.

Overall, the MARK series from Harman Stove Company showcases the commitment to delivering reliable, efficient, and aesthetically pleasing heating solutions. With advanced technologies, user-centric designs, and exceptional performance, each model provides a unique blend of features that cater to diverse heating needs, ensuring a cozy and comfortable environment for any home.