PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

(a)Do not operate or allow the oven to be operated with the door open.

(b)Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

(c)Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e)A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual.

If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS CORPORATION immediately @1-800-237-4277.

If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's Center for Devices and Radiological Health immediately.

Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.



Image 2
Contents Table of Contents 520LWBefore Servicing When the testing is completed Dont Touch Before ServicingLeakage test Microwave Measurement ProcedureRequirements 520LK/R-520LW Sharp PLAZA, MahwahMicrowave Ovens ForewordDescription SpecificationGeneral Information Grounding InstructionsOven Diagram Touch Control PanelDescription of Operating Sequence Power Level P-0 to P-90 CookingOperation OFF ConditionSensor Cooking Condition MicrowaveSchematic Clock Appears on DisplayDescription and Function of Components Troubleshooting Guide Problem Test ProceduresTest Procedure Procedure Component Test Letter Magnetron Assembly TestPower Transformer Test Procedure Component Test LetterMicrowave Output Power Magnetron Temperature Fuse Test Procedure Component Test Letter High Voltage Rectifier TestCavity Temperature Fuse Test High Voltage Capacitor TestRun the oven and check all functions Replace Temperature FusePrimary Interlock Switch Test Secondary Interlock System TestProcedure Component Test Letter Monitor Switch Test Touch Control Panel Assembly TestFigure of all digits flicker KEY Unit TestMenu 1ST Stage 2ND Stage 3RD Stage STEAKS/CHOPS Level Time Relay TestCompu Defrost Test Primary on the PWB, this foil pattern acts as a fuse Steps Occurrence Cause or CorrectionChecking the initial sensor cooking condition Testing Method for AH Sensor AND/OR Control UnitAH Sensor Test Sensor Dummy Resistor Circuit Checking Control UnitR1, R2 22Ω ± 1% 1/2W R3 4.3Ω ± 5% 1/4W R4 1MΩ ± 5% 1/4W Power Source Circuit Reset CircuitIndicator Circuit Synchronizing Signal CircuitDescription of LSI LSIPower source voltage Signal similar to ANI3Internal clock oscillation frequency control input setting Key strobe signalCommon data signal Converter power source voltage GND0VConverter power source voltage Operational Principle of Absolute Humidity Sensor Absolute Humidity Sensor CircuitStructure of Absolute Humidity Sensor Detector Circuit of Absolute Humidity Sensor CircuitServicing of Touch Control Panel Other PrecautionsTouch Control Panel Servicing Servicing ToolsTo prevent an electric shock, take the following pre Component Replacement and Adjustment ProcedureOuter Case Removal High Voltage Rectifier and High Voltage Capacitor Removal Power Transformer RemovalRe-install Magnetron RemovalGraphic Sheet and Membrane Switch Replacement Positive Lock Connector NO-CASE Type RemovalControl Panel Assembly Removal Oven Lamp and Lamp Socket RemovalInstallation Turntable Motor RemovalRemoval InstallationCooling FAN Motor Removal Rear ViewDoor Replacement After adjustment, check the followingSealer Film RE-INSTALLAfter any service, make sure of the following Diagram High Voltage ComponentsCircuit Control Unit Figure S-5 . Printed Wiring Board of Power Unit Parts List SCREWS,NUTS and Washers HOW to Order Replacement PartsMiscellaneous Model NumberOven and Cabinet Parts Control Panel Parts Door Parts Miscellaneous Packing and Accessories Copyright 2006 by Sharp Corporation ALL Rights Reserved

R-520LK, R-520LW specifications

The Sharp R-520LW and R-520LK are innovative microwave ovens that combine advanced technology with user-friendly features to enhance cooking experiences. Designed with modern kitchens in mind, these models embody efficiency, precision, and versatility.

One of the defining characteristics of both the R-520LW and R-520LK is their powerful 900-watt output, which allows for speedy cooking and reheating. This high wattage ensures that food is cooked evenly and retains its moisture, preventing the common issue of dry or unevenly heated meals. Furthermore, the inclusion of multiple cooking power levels provides users with flexibility, making it easy to select the ideal setting for various types of food.

Both models feature Sharp's signature Inverter Technology. Unlike traditional microwaves that use a turn-on and turn-off cycling method, inverter technology delivers a steady stream of cooking power. This results in more consistent heating, allowing delicate foods such as fish or custards to be cooked perfectly without overcooking the edges. This technology not only enhances the quality of cooked food but also improves the overall efficiency of the microwave.

The R-520LW and R-520LK come equipped with a variety of auto-cook settings that cater to different culinary needs. From popcorn to frozen vegetables, these pre-programmed settings allow users to prepare meals with just a touch of a button, making cooking uncomplicated for all skill levels. The large, user-friendly control panel features intuitive buttons and a digital display, ensuring effortless operation and visibility.

In terms of design, the R-520LW boasts a sleek white finish, while the R-520LK offers a modern black aesthetic. Both models are compact yet spacious, with a generous interior capacity that can accommodate a range of dish sizes. The turntable feature further enhances cooking efficiency by ensuring even cooking all around.

Cleaning and maintaining the R-520LW and R-520LK is a breeze, thanks to their easy-to-wipe surfaces and the interior's cavity that can be easily accessed. The durable construction of these microwaves means they are designed to withstand the rigors of daily use.

In summary, the Sharp R-520LW and R-520LK microwave ovens stand out with their advanced features, such as inverter technology and pre-programmed cooking settings, making them excellent choices for anyone looking to streamline their kitchen tasks. Their stylish designs and user-friendly interfaces further enhance their appeal, making them valuable additions to any modern home.