To turn Zone 2 on or off:
1.Press the
2.If Zone 2 is ON, pressing the ZONE but- ton a second time within 10 seconds turns it OFF. If Zone 2 is OFF, the second press of the ZONE button turns it ON with the last used input source and volume setting.
3.Following 10 seconds with no commands, the
To change the Zone 2 input source:
1.Press the
2.Within 10 seconds after pressing the ZONE button, press one of the INPUT SOURCE buttons to select a new source for Zone 2. The name of the selected source appears in the display.
3.Following 10 seconds with no commands, the
To change the Zone 2 volume:
1.Press the
2.Within 10 seconds after pressing the ZONE button, adjust the volume control to change the Zone 2 output level. The new setting appears in the display. This volume adjust- ment is only available using the VARIABLE output configuration. In FIXED output mode, the volume control for Zone 2 is disabled.
3.Following 10 seconds with no commands, the
Controlling Zone 2 from the Remote Location
With a properly configured IR repeater sys- tem, you have full control of Zone 2 using an
To turn Zone 2 on or off, press the POWER button on the remote. To adjust the volume in Zone 2, press the VOLUME buttons on the remote. To select a different analog input source, press one of the INPUT SOURCE but- tons on the remote.
When the TUNER source is not selected
in the main room, you can also access the tuner functions (Preset, Tuning Up/Down, Direct Preset Channel Selection, etc.) from ZONE 2. This feature is not available when the TUNER source is active in the main room to avoid interrupting someone else’s listening by changing the station.
Alternatively, you can control Zone 2 opera- tions from a keypad installed in the remote zone and connected to the KEYPAD input on the
NOTE: The volume adjustment is only avail- able if the Zone 2 outputs are configured to use VARIABLE levels. With FIXED levels, the volume control for Zone 2 is disabled.
Zone 2 Audio Outputs
See Figure 7
These
NOTE: Only analog input signals are avail- able at the Zone 2 outputs. Source compo- nents connected to only the digital inputs are not available in Zone 2.
Although you have the option of using an in- tegrated amplifier or a receiver to power the remote speakers, we suggest using a fixed- gain power amplifier. This simplifies system installation and operation. Your authorized Rotel dealer may make another recommendation based on specific system requirements.
To configure your system for Zone 2 opera- tion, connect the left and right Zone 2 outputs on the
NOTE: By default, the Zone 2 outputs provide a VARIABLE level signal, with control of the volume from the
ZONE REM IN Jack
See Figure 6
This 3.5 mm
NOTE: ZONE 2 and its IR repeater must be in a different location than
IR OUT Jacks
See Figure 6
The IR OUT 1 & 2 jacks send IR signals re- ceived at the ZONE REM IN jack or the EX- TERNAL REM IN jack to an infrared emitter placed in front of a source component or to Rotel CD players, cassette decks, or tuners with a compatible rear panel IR connector.
This output is used to allow IR signals from Zone 2 to be sent to the source components, or to pass along IR signals from a remote in the main room when the sensors on the source compo- nents are blocked by installation in a cabinet. See your authorized Rotel dealer for information on IR repeater systems.
NOTE: The EXT REM IN jack located to the right of these jacks is for use with an external IR sensor duplicating the