Zebra Technologies MIX05120 instruction sheet Installation and Operation, Metering Tip Selection

Page 1

Zebra Skimmers Corp.

MIX05120

Zebra® Economy Mixer Manual

Package Contains:

 

 

1.

Drum proportioner

4.

Metering tip kit (14 tips)

2.

Suction tube (4 ft.) with foot valve

5.

Product information sheet

3.Discharge tube (4 ft.) max length for delivery

THANK YOU FOR YOUR SUPPORT OF OUR PRODUCTS

Please use this equipment carefully and observe all warnings and cautions.

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - NOTE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

WEAR

protective clothing and eyewear when dispensing chemicals or other materials.

ALWAYS

observe safety and handling instructions of the chemical manufacturers.

ALWAYS

direct discharge away from you or other persons or into approved containers.

ALWAYS

dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise CAUTION when maintaining your equipment.

CLEAN

equipment after each use in accordance with instruction sheet.

WEAR

protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying equipment or changing metering tips.

ALWAYS

re-assemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.

ATTACH

only to tap water outlets (75 PSI maximum).

Installation and Operation:

1.Select a metering tip (see next section), and insert it into the suction stub. Slide the open end of the suction tube through the bung adaptor, then over the suction stub.

2.Slide end of discharge tube over the eductor discharge outlet.

3.Remove either the 3/4 or 2-inch bung from an upright drum.

4.Insert the foot valve end of the suction tube into the drum.

5.Swivel the drum adapter several turns in the bung opening until the bracket is secure.

6.Install minimum 1/2-inch ID water hose between the inlet swivel and water supply spigot. (Minimum 25 PSI flowing water pressure is required to operate the unit.)

7.Turn on water supply. To begin dispensing solution, open ball valve at inlet to unit. Do not keep discharge hose in liquid! The concentrate will siphon from the container.

Metering Tip Selection:

The final concentration of the dispensed liquid is related to both the size of the metering tip opening (orifice) and the viscosity of the liquid being siphoned. If product viscosity is noticeably greater than that of water, consult the procedure for Measurement of Concentration on the next page to achieve your desired water-to-product ratio. For waterthin products, use

the chart below as a guideline. Because such factors as inlet water pressure and temperature can affect dilution ratios, the figures listed below are only approximate. Test the actual dilution you are achieving using the Measurement of Concentration procedure for best results. Two undrilled, clear tips are supplied for drilling sizes not listed.

 

 

Decimal

Approximate Dilution Ratio at

 

Tip Color

Drill Size

Equivellent

40 PSI, water-thin viscosity (1.0 cp)

 

No tip

 

 

4.5:1

or 22.2%

 

Gray

30

.1285

5:1

20.0

 

Black

40

.0980

6:1

16.6

 

Beige

50

.0700

9:1

11.1

 

Red

55

.0520

20:1

5.0

 

White

57

.0430

24:1

4.16

 

Blue

60

.0400

26:1

3.84

 

Tan

65

.0350

31:1

3.23

Copyright 2008

Green

70

.0280

50:1

2.0

Zebra Skimmers Corp.

Orange

72

.0250

70:1

1.43

PO Box 833

Brown

74

.0225

90:1

1.11

Chagrin Falls, OH 44022

Yellow

76

.0200

100:1

1.0

888-249-4855

www.ZebraSkimmers.com

Purple

80

.0135

200:1

.50

 

Pink

87

.0100

400:1

.25

Printed in the USA • Revised February 2008

Image 1
Contents Metering Tip Selection Installation and OperationMeasurement of Concentration TroubleshootingParts Information