Zebra Skimmers Corp. | MIX05120 |
Zebra® Economy Mixer Manual
Package Contains: |
|
| |
1. | Drum proportioner | 4. | Metering tip kit (14 tips) |
2. | Suction tube (4 ft.) with foot valve | 5. | Product information sheet |
3.Discharge tube (4 ft.) max length for delivery
THANK YOU FOR YOUR SUPPORT OF OUR PRODUCTS
Please use this equipment carefully and observe all warnings and cautions.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - NOTE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WEAR | protective clothing and eyewear when dispensing chemicals or other materials. |
ALWAYS | observe safety and handling instructions of the chemical manufacturers. |
ALWAYS | direct discharge away from you or other persons or into approved containers. |
ALWAYS | dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise CAUTION when maintaining your equipment. |
CLEAN | equipment after each use in accordance with instruction sheet. |
WEAR | protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying equipment or changing metering tips. |
ALWAYS | |
ATTACH | only to tap water outlets (75 PSI maximum). |
Installation and Operation:
1.Select a metering tip (see next section), and insert it into the suction stub. Slide the open end of the suction tube through the bung adaptor, then over the suction stub.
2.Slide end of discharge tube over the eductor discharge outlet.
3.Remove either the 3/4 or
4.Insert the foot valve end of the suction tube into the drum.
5.Swivel the drum adapter several turns in the bung opening until the bracket is secure.
6.Install minimum
7.Turn on water supply. To begin dispensing solution, open ball valve at inlet to unit. Do not keep discharge hose in liquid! The concentrate will siphon from the container.
Metering Tip Selection:
The final concentration of the dispensed liquid is related to both the size of the metering tip opening (orifice) and the viscosity of the liquid being siphoned. If product viscosity is noticeably greater than that of water, consult the procedure for Measurement of Concentration on the next page to achieve your desired
the chart below as a guideline. Because such factors as inlet water pressure and temperature can affect dilution ratios, the figures listed below are only approximate. Test the actual dilution you are achieving using the Measurement of Concentration procedure for best results. Two undrilled, clear tips are supplied for drilling sizes not listed.
|
| Decimal | Approximate Dilution Ratio at |
| ||
Tip Color | Drill Size | Equivellent | 40 PSI, |
| ||
No tip |
|
| 4.5:1 | or 22.2% |
| |
Gray | 30 | .1285 | 5:1 | 20.0 |
| |
Black | 40 | .0980 | 6:1 | 16.6 |
| |
Beige | 50 | .0700 | 9:1 | 11.1 |
| |
Red | 55 | .0520 | 20:1 | 5.0 |
| |
White | 57 | .0430 | 24:1 | 4.16 |
| |
Blue | 60 | .0400 | 26:1 | 3.84 |
| |
Tan | 65 | .0350 | 31:1 | 3.23 | Copyright 2008 | |
Green | 70 | .0280 | 50:1 | 2.0 | Zebra Skimmers Corp. | |
Orange | 72 | .0250 | 70:1 | 1.43 | PO Box 833 | |
Brown | 74 | .0225 | 90:1 | 1.11 | Chagrin Falls, OH 44022 | |
Yellow | 76 | .0200 | 100:1 | 1.0 | ||
www.ZebraSkimmers.com | ||||||
Purple | 80 | .0135 | 200:1 | .50 | ||
| ||||||
Pink | 87 | .0100 | 400:1 | .25 | Printed in the USA • Revised February 2008 |