Yeoman YM-W9001FL manual Appliance Commissioning Checklist, Dealer appliance was purchased from

Page 3

APPLIANCE COMMISSIONING CHECKLIST

To assist us in any guarantee claim please complete the following information.

In the unlikely event of a problem, contact your installer or dealer for assistance:

Dealer appliance was purchased from

Name:......................................................................................................................................................................................

Address:...................................................................................................................................................................................

................................................................................................................................................................................................

Telephone number:.................................................................................................................................................................

Essential Information - MUST be completed

Date installed:..........................................................................................................................................................................

Model description:...................................................................................................................................................................

Serial number:.........................................................................................................................................................................

Installation Engineer

Company name:......................................................................................................................................................................

Address:...................................................................................................................................................................................

................................................................................................................................................................................................

Telephone number:.................................................................................................................................................................

Commissioning Checks (to be completed and signed)

Is flue system correct for the appliance

YES

NO

Flue swept and soundness test complete

YES

NO

Smoke test completed on installed appliance

YES

NO

Spillage test completed

YES

NO

Use of appliance and operation of controls explained

YES

NO

Instruction book handed to customer

YES

NO

Clearance to combustible materials checked

YES

NO

Signature:

Print name:

................................................................

3

Image 3
Contents Exmoor/Exe/Devon/County Installation Instructions Commissioning User Instructions Maintenance & ServicingBasic Spare Parts List Service RecordsEssential Information Must be completed Appliance Commissioning ChecklistInstallation Engineer Dealer appliance was purchased fromAIR Controls User InstructionsGeneral points Serial NumberDoor Handle Using the Appliance for the First TimeAirwash & Primary AIR Controls Secondary AIR ControlsLighting the appliance Recommended FuelsRunning The appliance Burning Wood with or without Multi-fuel kit fittedBurning Solid fuel with Multi-fuel kit fitted Air inlets puffing smoke Burning tipsFuel Quality Wood Fuel Quality Solid FuelAsh removal OVER-FIRING General CleaningCleaning Glass Extended burningSeasonal use Troubleshooting tipsChimney Sweeping Care of stoveAppliance is producing tar This is identified by Glass crackingPacking List Technical SpecificationSTANDARD FEATURES Yeoman EXMOOR/EXE/DEVON/COUNTYYeoman Stove Dimensions Site RequirementsDescription Dia Additional Flue & ChimneyMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Flue PlateFlue Exit Positions Hearth DimensionsWalls Next to Hearth SITE REQUIREMENTSPRE-INSTALLATION Checks FluesAdditional Ventilation Ventilation Legal requirements Installation InstructionsInstalling the Stove Top flue installationFitting & Removal of the Baffle Removal of the LOG GuardFitting & Removal of the riddling mechanism Fitting and Removal of the FirebricksCounty Model Exmoor, Exe & Devon ModelsCommissioning CommissioningGive the copy of the Instructions to the customer Task Product Name Annual ServiceFitting A NEW Door Glass Fitting and Removal of the BAFFLEFitting and Removal OF FIREBRICKS Fitting and Removal of the riddling mechanismALL Models Adjusting Door CatchBasic Spare Parts List Exmoor, Exe, Devon, County codes Exmoor, Exe, Devon, County Single Door Exe, Devon, County Double Door Service Records Page Greg Taylor Technical Director

YM-W9001FL specifications

The Yeoman YM-W9001FL is a versatile and efficient wood-burning stove that combines modern technology with classic design. This stove offers an impressive balance between functionality, aesthetic appeal, and sustainability. Its robust build quality and sleek lines make it an attractive addition to any home, while its operational features ensure optimal performance.

One of the standout features of the YM-W9001FL is its efficient combustion technology. The stove is designed to maximize heat output while minimizing emissions. With an impressive efficiency rating, this stove burns wood more completely, producing less smoke and particulate matter. This makes it not only an environmentally friendly choice but also a cost-effective one, allowing homeowners to save on fuel while enjoying consistent warmth.

The YM-W9001FL is equipped with a large viewing window, allowing users to enjoy the mesmerizing flames while maintaining effective heat distribution. The air wash system ensures that the glass stays clean, providing an unobstructed view of the fire. The design also includes a modern control system that regulates airflow, thus enhancing combustion efficiency and enabling users to manage the fire's intensity effortlessly.

In terms of size, the YM-W9001FL is compact but efficient, making it suitable for a variety of spaces, from cozy cabins to contemporary homes. The stove is available in a range of finishes, enabling homeowners to select a style that complements their interior décor. This versatility extends to its installation options, as the stove can be installed as a freestanding unit or fitted into an existing fireplace.

The stove meets stringent regulatory standards for emissions and is built with high-quality materials to ensure durability and longevity. Its cast iron construction provides excellent heat retention, allowing it to stay warm long after the fire has died down. Furthermore, it features an easy-to-clean design, with removable ash pans that simplify maintenance.

Overall, the Yeoman YM-W9001FL is a sophisticated choice for those seeking an efficient, environmentally friendly wood-burning stove that does not compromise on style or performance. Its blend of innovative technology, timeless design, and user-friendly features make it an excellent investment for any homeowner looking to enhance their living space with the warmth and ambiance of a real fire.