THERMOSTAT CALIBRATION

1.Turn on unit. Set control dial at desired temperature.

2.Allow control to cycle at least three times (3) and observe temperature at the middle of the fourth cycle.

3.If calibration is required, carefully remove dial knob. Do not turn shaft.

4.Turn calibration screw in center of dial shaft clockwise to lower temperature and counter-clockwise to increase temperature.

5.Allow unit to cycle three (3) times and observe temperature at middle of fourth cycle. Readjust calibration screw if necessary. Replace dial knob.

RECOMMENDED SPARE PARTS

When it is critical to have continuous operation of this unit, we suggest having the following spare parts on hand:

1.Heating Element

2.Thermostat

3.Power Cord

K-NP Wiring Diagram 120V / 500W

Temperature

Sensor

Thermostat

# 301037

Neon Pilot #301085

Oven Ground

Heating Element #301022

- 6 -

Image 6
Contents Henkel, Inc Box Hammond, LA 70404 985 One Year Limited Warranty Henkel, IncSafety Precautions General InformationOperation Temperature SettingScheduled Maintenance Guide To StorageIf Oven Overheats Corrective MaintenanceIf Oven Fails to Operate no Heat Changing the Heating ElementNP Wiring Diagram 120V / 500W Thermostat CalibrationRecommended Spare Parts