Flux and Electrode Stabilizing Guide

 

Air Conditioned

Dry Rod

After Exposure to Moisture a

Type (AWS)

Storage

Oven Holding

Sufficient Time to affect Weld Quality

 

Before Opening

After Opening

Recondition

Rebake

 

 

 

Step 1

Step 2

Standard

 

 

180°F ± 25°

240°F ± 25°

EXX10

 

 

two hours

one hour

EXX11

80°F ± 20°

140°F ± 30°

 

 

 

 

EXX12

 

 

60% ± 10% RH

 

 

EXX13

 

Three hour total

 

 

EXX20

 

 

 

 

EXX30

 

 

 

 

Iron Powder

90°F ± 20°

 

180°F ± 25°

325°F ± 25°

EXX14

140°F ± 30°

two hours

one hour

EXX24

50% RH max

Three hour total

 

EXX27

 

 

 

 

 

 

Iron Powder-

 

 

180°F ± 25°

700°F ± 100°

Low Hydrogen

90°F ± 20°

400°F ± 50°

two hours

one-half hour

EXX18

50% RH max

Two & one-half hour total

 

EXX28

 

 

 

 

 

 

Low Hydrogen

90°F ± 20°

 

180°F ± 25°

600°F ± 100°

EXX15

400°F ± 50°

two hours

one-half hour

50% RH max

EXX16

 

Two & one-half hour total

 

 

Low-Hydrogen

 

 

180°F ± 25°

700°F ± 100°

High Tensile

90°F ± 20°

400°F ± 50°

two hours

one-half hour

EXXX15

50% RH max

Two & one-half hour total

 

EXXX16

 

 

 

 

 

 

Stainless

 

 

180°F ± 25°

350°F ± 50°

Inconel

 

 

 

 

one hour

one hour

Monel

 

 

90°F ± 20°

 

 

 

Nickel

225°F ± 50°

 

 

Brasses

50% RH max

 

 

 

Two hour total

Bronzes

 

 

Hard Surfacing

 

 

 

 

Special Alloys

 

 

 

 

Granulated or

90°F ± 20°

240° F ± 50°

Not required

700°F ± 100°

Agglomerated

50% RH max

two hours

Flux

 

 

 

 

IMPORTANT:

This table is offered as a guide to proper storage and oven holding temperatures for the most common electrodes in use today. In addition, recondition/rebake procedures for electrode coatings that have been exposed to moisture for a sufficient period of time to affect the weld quality are included. Good judgment and the manufacturer’s recommendations should be your guide.

Note: In the HTS Stainless electrode groups, and 15 & 16 type coatings, there can be a greater difference in the maximum temperature requirements for rebaking than those shown. This can be handled by special request to the particular manufacturer involved.

CONTACT YOUR ELECTRODE MANUFACTURER FOR SPECIFIC INFORMATION INVOLVING CRITICAL OPERATIONS.

Electrode coating should not be exposed to the rebaking temperature without first having been reconditioned at a lower temperature. Failure to observe this rule will result in breakdown of electrode coatings.

After rebake, lower temperature to holding level until reissue.

Image 8
Contents Henkel, Inc Box Hammond, LA 70404 985 Henkel, Inc Model KF-100A Flux Holding Oven SpecificationsOne Year Limited Warranty Safety Precautions General InformationTemperature Setting OperationGuide to Storage Functional DescriptionTroubleshooting Scheduled MaintenanceIf Oven Heats but Fails to Reach Temperature If Oven Fails to Operate no HeatChanging the Thermostat Corrective MaintenanceChanging the Heating Elements Model KF-100A Repair Parts List Quantity Description Part NumberHENKEL, INC